Overview

Starting from Windows Vista, Microsoft introduced the Boot Configuration Data (BCD). BCD files provide a data store that describes boot applications and their settings.

BCDEdit is a command-line tool you can use to manage BCD stores. You can use this command-line tool to create new stores, modify existing stores, add boot menu parameters, and perform other tasks.

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.

As I mentioned earlier, Microsoft introduced BCD and BCDEdit from Windows Vista. This meant that BCDEdit replaced the Boot (.ini) file while BCDEdit.exe replaced Bootcfg.exe.

Popular on Amazon
RisoPhy Mechanical Gaming Keyboard, RGB 104 Keys Ultra-Slim LED Backlit USB Wired Keyboard with Blue Switch, Durable Abs Keycaps/Anti-Ghosting/Spill-Resistant Computer Keyboard for PC Mac Xbox Gamer
  • 【Mechanical Keyboard: Responsive BLue Switches】RisoPhy PC keyboard features clicky keys which offer you higher accuracy and quicker response with an enjoyable click sound when typing.This keyboard is more comfortable to type on since it features deeper key travel,greater feedback,and more space between keys.For those who prefer keyboards with a more tactile and "clicky" feel,our keyboard with BLUE switches is a nice choice.
  • 【Rainbow Backlit Keyboard: illuminate Your Desktop】With 9 different backlights,5 levels of light speed and brightness,this computer keyboard enriches your gaming experience and improves your mood greatly,which is a great addition to your desktop,especially in the dark.Plus,the ultra-durable double injection ABS engineered keycaps provide crystal clear uniform backlight and greatly improve your typing accuracy at night.
  • 【High-end 104 Keys Full-Size Keyboard】The Win lock function frees your worry about mistyping when gaming(Fn+Win).Keycaps are pluggable and easy to clean,saving you much unnecessary trouble.We designed 4 hydrophobic holes for this keyboard,allowing water to flow away quickly to prevent damage to the keyboard.No longer afraid of accidents.(✦Include a keycaps puller for cleaning or other needs.)
  • 【Advanced Ergonomic Comfort】This PC gamer Keyboard adopts a scientific stair-up keycap design that keeps your arms in the most natural state to minimize hand fatigue for long time use.In order to improve your posture and make you more comfortable during use,the wired keyboard comes with 2 strong foldable rear kickstands to slope it.Moreover,the keyboard is non-slip enough because there are 4 rubber padding underneath the keyboard.
  • 【100% Anti-Ghosting & 12 Multimedia Combinations】100% anti-ghosting gaming keyboard allows all keys to work simultaneously,no matter how fast you type.12 multimedia key shortcuts allow you to quickly access to calculator/media/volume control/email.RisoPhy mechanical gaming keyboard with the number pad greatly improves your productivity.This ultra-durable keyboard with up to 50 million keystrokes life works well with Windows 7/8/10/XP/VISTA/95/98/XP/2000/ME/VISTA and Mac OS Xbox etc.

However, BCDEdit.exe introduced some added benefits compared to Bootcfg.exe. For example, BCDEdit.exe offers a wider range of boot parameters.

In addition to that, BCDEdit.exe also provides improved scripting support than Bootcfg.exe. In the next sections of this guide, I will explain the capabilities of BCDEdit.exe, starting with its syntaxes in the next section.

Syntax of the BCDEdit Command-Line Tool

The syntax of the BCDEdit command is…

BCDEdit /command [<argument1>] [<argument2>] ...

The syntax has the “/command” switch, known as “topics.” Then, each “/command” switch has some arguments.

Free tools Windows power users keep installed

One-click scans. No signup required.

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.

To display all available BCDEdit “/command” switches (or “topics.”), run the command below.

BCDEdit /? Topics

The above command displays all the available “topics.” If you look closely, you’ll notice that the result includes what I may call “standard” “/command” switches like /bootdebug and /bootems.

Moreover, if you look towards the bottom of the result, you’ll see a list that starts with “TYPES”. More on this in subsequent sections.

To display information about a BCDEdit, for example, /bootdebug run a command like the one below.

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.
BCDEdit /? /bootdebug

The command displays the specific syntax of the BCDEdit command. Then, it also displays the arguments available to the command and what they mean.

Most importantly, you also get some examples.

Moreso, to get more information about available BCDEdit data “TYPES,” options and how to use them, run the command below.

BCDEdit /? TYPES

This last command displays available TYPES and offers brief explanations about them.

Furthermore, to get more help with a specific data TYPE, run the command with this syntax.

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.
BCDEdit /? <TYPE NAME>

For example, to get more information about the BOOTAPP TYPE, I’ll run the command below.

BCDEdit /? TYPES BOOTAPP

Here is the result of the command.

In the subsequent sections, I will dive deep into the various elements of the BCDEdit command. I will start with a detailed explanation of the BCEDit command options and their arguments in the next section.

BCDEdit Command-line Options and their Arguments

BCEDit Command-line Options And Their Arguments

In the subsections of this section, I’ll explain the command-line options (commands or topics) shown in the screenshot above.

As I mentioned earlier, to learn about any of the topics, run a command with the syntax below.

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.
BCDEdit /? </command>
Replace </command> with the topic you want to learn

BCDEdit /bootdebug Command Syntax and Arguments

The /bootdebug command option enables or disables the boot debugger for the specified boot entry. Although this command works for any entry, it is only effective for boot applications.

The syntax of the /bootdebug command is…

BCDEdit /bootdebug [<id>] { ON | OFF }

<id> specifies the identifier of the entry to be modified. An identifier uniquely identifies entries contained in a BDC store.

BCDEdit /bootems Command Syntax and Arguments

The /bootems command enables or disables Emergency Management Services for the
specified entry. The syntax of the /bootems command is…

BCDEdit /bootems [<id>] { ON | OFF }

<id> specifies the identifier of the entry to be modified. An identifier uniquely identifies entries contained in a BDC store.

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.

BCDEdit /bootsequence Command Syntax and Arguments

The /bootsequence command sets the one-time boot sequence to be used by the boot manager. The syntax of this command is…

BCDEDit /bootsequence <id> [...] [ /addfirst | /addlast | /remove ]

The table below explains the arguments of the /bootsequence command syntax.

BCDEdit /bootsequence ArgumentMeaning/Notes
<id>The <id> argument specifies the identifier of the entry to be modified. An identifier uniquely identifies entries contained in a BDC store.
/addfirst/addfirst argument adds the specified entry identifier to the top of the boot sequence. If this switch is specified, only a single identifier may be specified. If the identifier is already in the list, it is moved to the top of the list.
/addlastThe /addlast argument adds the specified entry identifier to the end of the boot sequence. If this switch is specified, only a single identifier may be specified. If the identifier is already in the list, it is moved to the end of the list.
/remove/remove argument removes the specified entry identifier from the boot sequence. If this switch is specified, only a single entry identifier may be specified. If the identifier is not in the list then the operation has no effect. If the last entry is being removed, then the boot sequence value is deleted from the boot manager entry.

BCDEdit /copy Command Syntax and Arguments

The /copy command creates a copy of the specified boot entry. The syntax of this command is…

BCDEdit [/store <filename>] /copy {<id>} /d <description>

In the table below I have explained each argument…

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.
BCDEdit /copy ArgumentMeaning/Notes
/store <filename>The <filename> argument specifies the BCD store to use. If this option is not specified, the command will use the system store.
<id>The <id> argument specifies the identifier of the entry to be copied.
/d <description>Specifies the description to be applied to the new entry.

BCDEdit /create Command Syntax and Arguments

The /create command creates a new entry in the boot configuration data store. If a well-known identifier is specified, then the /application, /inherit and /device options cannot be specified.

On the contrary, if a well-known identifier is not specified, or if is not well-known, then you must specify an /application, /inherit or /device option.

The syntax of this command is…

BCDEdit /create [{<id>}] [/d <description>] [/application <apptype> | /inherit [<apptype>] | /inherit DEVICE | /device]

In the table below I have explained each argument…

BCDEdit /create ArgumentMeaning/Notes
<id>The <id> argument specifies the identifier to be used for the new entry
/d <description>Specifies the description to be applied to the new entry.
/application <apptype>Specifies that the new entry must be an application entry. <apptype> specifies the application type. <apptype> can be BOOTAPP, BOOTSECTOR, OSLOADER, RESUME or STARTUP
/inherit <apptype>The /inherit argument specifies that the new entry must be an inherit entry, and <apptype> specifies the application type. If /inherit is not specified, then the entry can be inherited by any entry. However, if /inherit is specified, <apptype> can be one of the following: BOOTMGR, BOOTSECTOR, FWBOOTMGR, MEMDIAG, NTLDR, OSLOADER, or RESUME

BCDEdit /createstore Command Syntax and Arguments

The BCDEdit /createstore command creates a new empty boot configuration data store. The store created with this command is not a system store.

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.

The syntax of the /createstore command is…

BCDEdit  /createstore <filename>

/createstore <filename> specifies the filename of the boot configuration data store. If the filename contains spaces, it must be enclosed in quotation marks (“”).

BCDEdit /dbgsettings Command Syntax and Arguments

The /dbgsettings command sets or displays the global debugger settings for the system. It does not enable or disable the debugger for any particular boot entry.

The syntax of the /dbgsettings command is…

BCDEdit /dbgsettings [ <debugtype> [DEBUGPORT:<comport>] [BAUDRATE:<baud>] [CHANNEL:<channel>] [TARGETNAME:<targetname>] [HOSTIP:<ip>] [PORT:<port>] [KEY:<key>] [nodhcp] [newkey] [/start <startpolicy>]  [/noumex] ]

In the table below, I have explained the arguments of the syntax.

BCDEdit /dbgsettings ArgumentMeaning/Notes
<debugtype>Specifies the type of debugger. You can specify SERIAL, 1394, USB, NET, or LOCAL.
DEBUGPORT: <comport>If you specify SERIAL debugging, you can use <comport> to specify the serial port to use as the debugging port. This is an optional setting.
BAUDRATE:<baud>This argument is also applicable to SERIAL debugging. Use it to specify the baud rate to be used for debugging. This is an optional setting.
CHANNEL:<channel>If you specify1394 debugging, use <channel> to specify the 1394 channel to be used for debugging.
TARGETNAME:<targetname>This argument is used to specify the USB target name to be used for debugging if you specify USB debugging as the <debugtype>.
HOSTIP:<ip>For network (NET) debugging. <ip> specifies the IPv4 address of the host debugger.
PORT:<port>This also applies to the network (NET) debugging <debugtype>. Use <port> to specify the port to communicate with on the host debugger. This value should be 49152 or higher.
KEY:<key>For network debugging as well. <key> specifies the key with which to encrypt the connection. Values can be [0-9] and/or [a-z].
nodhcpnodhcp applies to network debugging. When you specify nodhcp, it prevents the use of DHCP to obtain the target IP address.
newkeyApplies to network debugging – specifies that a new encryption key should be generated for the connection.
/start <startpolicy>This argument applies to all debugger types (<debugtype>). /start <startpolicy> specifies the debugger start policy. You can use one of the following: ACTIVE, AUTOENABLE, DISABLE. If you do not specify not specify <startpolicy>, ACTIVE is the default.
/noumexIf you specify the /noumex argument, this causes the kernel debugger to ignore any user-mode exceptions.
The /dbgsettings command has an alias – /eventsettings. So, you can use /eventsettings instead of /dbgsettings.

BCDEdit /debug Command Syntax and Arguments

This command enables or disables the kernel debugger for the specified boot entry. The syntax of the BCDEDit /debug command is…

What’s actually slowing this PC down?

Pick the symptom - the matching free tool is one click away.

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.
BCDEdit /debug [<id>] { ON | OFF }

<id> specifies the identifier of the entry to be modified. You can only specify Windows boot loader entries. If you do not specify a boot loader identifier, the BCDEDit /debug command will use {current}.

BCDEdit /default Command Syntax and Arguments

The BCDEdit /default command sets the default entry that the boot manager will use when the timeout expires.

The syntax of this command is…

BCDEdit /default <id>

<id> specifies the identifier of the boot entry to be used as the default when the time-out expires.

BCDEdit /delete Command Syntax and Arguments

The BCDEdit /delete command deletes an entry from the boot configuration data store.

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.
Also popular on Amazon
Sale
Redragon K582 Wired RGB Mechanical Gaming Keyboard, 104-Key Standard Layout | 16.8M Color Immersive eSports Lighting Vibe, N-Key Rollover for Accurate Combos, 50M-Keystroke Durability, Customize Software
  • Smooth, Effortless Keystrokes for Work and Play - Linear red switches need less force and give a straight, responsive press with no tactile bump, so long sessions feel light on your fingers.
  • Every Combo Registers, Wide Compatibility - 100% anti-ghosting with N-key rollover plus a gold-plated USB connector that works reliably across Windows and Mac.
  • 16.8 Million Colors for a True eSports Vibe - 6 lighting themes and 18 backlight modes let you dial in exactly the glow you want, with brightness adjustable right from the keyboard.
  • Built to Outlast Daily Gaming - Rated for 50 million keystrokes on a solid base, so the board holds up to years of heavy typing and gaming without keys feeling mushy.
  • Reassign Any Key, Pro Software for Deeper Customization - Fully programmable keys let you remap layouts or set macros, and the companion software lets you design your own lighting effects and keybindings.

The parameter of the /delete command is…

BCDEdit [/store <filename>] /delete <id> [/f] [/cleanup | /nocleanup]

The table below lists and explains the arguments in the above syntax.

BCDEdit /delete ArgumentMeaning/Notes
/store <filename>Use the /store <filename> argument to specify the store to be used. If this option is not specified, the system store is used.
<id>Specifies the identifier of the boot entry that you want to delete.
/fDeletes the specified entry. Without this option, Bcdedit will not delete any entries that have a well-known identifier.
/cleanupDeletes the specified entry and removes the entry from the display order. Any other references to the entry being deleted will also be removed from the store. When deleting an OS loader entry, the associated resume from hibernation entry is also deleted if any other OS loaders do not reference it. This option is assumed unless /nocleanup is specified.
/nocleanupDeletes the specified entry without removing the entry from the display order.

BCDEdit /deletevalue Command Syntax and Arguments

The BCDEdit /deletevalue command deletes a data element from an entry in the boot configuration data store.

The syntax of the BCDEdit /deletevalue command is…

BCDEdit [/store <filename>] /deletevalue [<id>] <datatype>

I have explained the arguments in the syntax in the table below.

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.
BCDEdit /deletevalue ArgumentMeaning/Notes
/store <filename>Use the /store <filename> argument to specify the store to be used. If you do not specify this option, the /deletevalue command will use the system store.
<id>Specifies the identifier of the entry that will be modified. If not specified, {current} is used.
<datatype>Specifies the option that will be removed from the specified entry.

BCDEdit /displayorder Command Syntax and Arguments

The BCDEdit /displayorder command sets the display order to be used by the boot manager.

The syntax of the command is…

BCDEdit /displayorder <id> […] [ /addfirst | /addlast | /remove ]

In the table below, I have explained the arguments in the syntax.

BCDEdit /displayorder ArgumentMeaning/Notes
<id> […]Specifies a list of identifiers that make up the display order – the identifiers must be separated by spaces. At least one identifier must be specified.
/addfirstThe /addfirst argument adds the specified entry identifier to the top of the display order. If this switch is specified, only a single entry identifier may be specified. If the specified identifier is already in the list, it will be moved to the top of the list.
/addlast/addlast adds the specified entry identifier to the end of the display order. If this switch is specified, only a single entry identifier may be specified. If the specified identifier is already in the list, it is moved to the end of the list.
/removeThe /remove argument removes the specified entry identifier from the display order. If /remove is specified, only a single entry identifier may be specified. If the identifier you specified is not in the list then the BCDEdit /displayorder command will no effect. If the last entry is being removed, then the display order value is deleted from the boot manager entry.

BCDEdit /event Command Syntax and Arguments

The BCDEdit /event command enables or disables the remote event logging for the specified boot entry.

The syntax of the command is…

BCDEdit /event [<id>] { ON | OFF }

<id> specifies the identifier of the Windows boot manager entry to be modified. Only Windows boot loader entries may be specified.

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.

If you do not specify an identifier with the <id> argument, the command will use {current} as the identified.

BCDEdit /ems Command Syntax and Arguments

The BCDEdit /ems command enables or disables Emergency Management Services for the specified operating system boot entry.

The syntax of the BCDEdit /ems command is…

BCDEdit /ems [<id>] { ON | OFF }

<id> specifies the identifier of the Windows boot manager entry to be modified. The <id> argument only supports “Windows boot loader” entries.

If you do not specified, {current} is used.

BCDEdit /emssettings Command Syntax and Arguments

The /emssettings command sets the global Emergency Management Services settings for the system. Emssettings does not enable or disable Emergency Management Services for any particular boot entry.

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.

The syntax of /emssettings command is…

BCDEdit /emssettings [ BIOS ] | [ EMSPORT:<port> | [EMSBAUDRATE:<baudrate>] ]

This table explains the arguments.

BCDEdit /emssettings ArgumentMeaning/Notes
BIOSThe BIOS argument specifies that the system will use BIOS settings for the Emergency Management Services configuration. This works only on systems that have Emergency Management Services support provided by the BIOS.
EMSPORT:<port>Specifies the serial port to use as the Emergency Management Services port. You cannot specify this argument with the BIOS argument.
EMSBAUDRATE:<baudrate>The “EMSBAUDRATE:<baudrate>” argument specifies the serial baud rate to use for Emergency Management Services. This command should not be specified with the BIOS option. This is an optional argument – the default is 9,600 baud.

BCDEdit /enum Command Syntax and Arguments

The BCDEdit /enum command lists entries in a store. The /enum command is the default, so running “bcdedit” without parameters is equivalent to running “bcdedit /enum ACTIVE”.

The syntax of the /enum command is…

BCDEdit [/store <filename>] /enum [<type> | <id>] [/v]

I have explained the arguments in the table below.

BCDEdit /emssettings ArgumentMeaning/Notes
/store <filename>Use the /store <filename> argument to specifies the store to be used. If this option is not specified, the command will use the system store.
<type> The <type> argument specifies the type of entries to be listed. You can specify one of the following as the <type> – ACTIVE, FIRMWARE, BOOTAPP, BOOTMGR, OSLOADER, INHERIT, ALL
<id>Use the <id> argument to specify the identifier of the entry to be listed. If an identifier is provided, then only the specified object will be listed.
/vDisplays entry identifiers in full, rather than using names for well-known identifiers. Read about well-known identifiers in the “Well-known BCD Store Identifiers” section later in this guide.

BCDEdit /export Command Syntax and Arguments

Use this command to export the contents of the system store to a file. You can then use the file to restore the state of the system store if you ever need to do that.

The BCDEdit /export command is only valid for the system store.

The syntax of BCDEdit /export is…

bcdedit /export <filename>

/export <filename> is the filename to be used as the destination for the export. If the filename contains spaces, you must be enclose it in quotation marks (“”).

Free tools Windows power users keep installed

One-click scans. No signup required.

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.

BCDEdit /import Command Syntax and Arguments

The BCDEdit /import command restores the state of the system store using a backup data file previously generated using the /export command. The command deletes All existing entries in the BCD system store before the import takes place.

This command is only valid for the system store.

The syntax of the /import command is…

BCDEdit /import <filename> [/clean]

/import <filename> is the name of the file that is imported into the system store. If the filename contains spaces, it must be enclosed in quotation marks (“”).
/clean specifies that all existing firmware boot entries should be deleted (only affects EFI systems).

BCDEdit /hypervisorsettings Command Syntax and Arguments

The BCDEdit /hypervisorsettings command sets or displays the hypervisor settings for the system. This command does not disable or enable the hypervisor debugger for any
specific OS loader entry.

If you want to enable or disable the hypervisor debugger for an Operating System loader entry, run the command with the syntax below.

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.
BCDEdit <identifier> /set HYPERVISORDEBUG ON

The syntax of BCDEdit /hypervisorsettings command is…

bcdedit /hypervisorsettings [ <debugtype> [DEBUGPORT:<port>] [BAUDRATE:<baud>] 
[CHANNEL:<channel>] [HOSTIP:ip>] [PORT:<port>] ]

The arguments are explained in the table below.

BCDEdit /hypervisorsettings ArgumentMeaning/Notes
<debugtype>Use <debugtype> to specify the type of debugger. You can use SERIAL, 1394, or NET for this argument
DEBUGPORT:<port>When you use the SERIAL debugging <debugtype>, use <port> to specify the serial port to use as the debugging port.
BAUDRATE:<baud>This argument also works when you specify SERIAL debugging <debugtype>. Use <baud> to specify the baud rate to be used for debugging.
CHANNEL:<channel><channel> applies to the 1394 debugging <debugtype>. Use <channel> to specify the 1394 channel to be used for debugging.
HOSTIP:<ip>For network debugging <channel>. <ip> specifies the IPv4 address of the host debugger.
PORT:<port>For network debugging <channel>. <port> specifies the port to communicate with on the host debugger. You should specify 49152 or higher.

BCDEdit /mirror Command Syntax and Arguments

The BCDEdit /mirror command creates a mirror of the specified boot entry. The syntax of this command is…

BCDEdit [/store <filename>] /mirror {<id>}

/store <filename> specifies the store to be used. If this option is not specified, the system store is used. <id> specifies the identifier of the entry to be mirrored.

BCDEdit /set Command Syntax and Arguments

The BCDEdit /set command sets an entry option value in the boot configuration data store. The syntax of the /set command is…

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.
BCDEdit [/store <filename>] /set [{<id>}] <datatype> <value> [ /addfirst | /addlast | /remove ]

In the table below, I have explained the arguments in the syntax.

BCDEdit /store ArgumentMeaning/Notes
/store <filename>Use the <filename> argument to specify the store BCDEDit should use for the /set command. If you do not specify the <filename> argument, the /set command will use the system store.
<id>The <id> argument specifies the identifier of the entry to be modified. If not specified, {current} is used.
<datatype><datatype> specifies the option data type that will be created or modified. For more information about data types, run the “bcdedit /? TYPES” command. I have a section later in this guide that explains the data types.
<value>Use the <value> argument to specify the value that should be assigned to the option. The format of <value> depends on the data type specified. To learn about data formats, run the “bcdedit /? FORMATS”. I have a section dedicated to explaining the different data type formats later in this guide.
/addfirstThe /addfirst argument adds the specified entry identifier to the top of the list. If you specify this argument, only a single entry identifier may be specified. If the specified identifier is already in the list, it will be moved to the top of the list. You can only use this argument if datatype is an object list.
/addlastThe /addlast argument adds the specified entry identifier to the end of the list. If you specify this argument, only a single entry identifier may be specified. If the specified identifier is already in the list, it will be moved to the end of the list. You can only use this argument if datatype is an object list.
/removeUse the /remove argument to remove the specified entry identifier from the list. If you specify this argument, only a single entry identifier may be specified. If the identifier is not in the list, then the operation has no effect. However, if you’re removing the last entry, then the datatype value will be deleted. You can only use this argument if datatype is an object list.

BCDEdit /store Command Syntax and Arguments

Use the BCDEdit /store command-line option to specify the store to be used. If this option is not specified, then the system store is used.

You cannot use the /store argument with the /createstore, /import, or /export commands. The general syntax for the /store command argument is…

BCDEdit /store <filename>

Use <filename> to specify the file name of the boot configuration data store. If the file name contains spaces, you must enclose it in quotation marks (“”).

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.

BCDEdit /timeout Command Syntax and Arguments

The BCDEdit /timeout command sets the time to wait, in seconds, before the boot manager selects a default entry to boot.

The syntax of the /timeout command is…

BCDEdit /timeout <timeout>

Use <timeout> to specify the time to wait, in seconds, before the boot manager selects a default entry to boot.

BCDEdit /toolsdisplayorder Command Syntax and Arguments

The /toolsdisplayorder command sets the display order to be used by the boot manager when displaying the tools menu.

The syntax of the command is…

BCDEdit /toolsdisplayorder <id> [...] [ /addfirst | /addlast | /remove ]

In the table below, I have listed and explained the arguments of the syntax above…

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.
BCDEdit /toolsdisplayorder ArgumentMeaning/Notes
<id> […]Specifies a list of identifiers that make up the tools display order. You must specify at least one identifier and they must be separated by spaces.
/addfirst/addfirst adds the specified entry identifier to the top of the tools display order. If this switch is specified, only a single entry identifier may be specified. If the specified identifier is already in the list, it is moved to the top of the list.
/addlast/addlast adds the specified entry identifier to the end of the tools display order. If this switch is specified, only a single entry identifier may be specified. If the specified identifier is already in the list, it is moved to the end of the list.
/remove/remove removes the specified entry identifier from the tools display order. If this switch is specified, only a single entry identifier may be specified. If the identifier is not in the list, then the operation will have no effect. If the last entry is being removed, then the
tools display order value is deleted from the boot manager entry.

BCDEdit /v Command Syntax and Arguments

By default, when you run BCDEdit, any well-known entry identifiers are replaced by their friendly shorthand form. Specifying /v as a command-line switch prevents this replacement and displays all identifiers in full.

Running “bcdedit /v” by itself is equivalent to running “bcdedit /enum ACTIVE /v”.

Well-known BCD Store Identifiers

In the last subsection, I discussed the syntaxes and arguments of the BCDEDit commands. Most of them an <id> argument that specifies the unique identifier or GUID for the BCD sore.

Also popular on Amazon
Sale
Redragon K556 Wired RGB Mechanical Gaming Keyboard, 104-Key Aluminum Board | Rock-Solid Metal Build, 20 Backlits Immersive ESports Vibe, Hot-swap Comfortable Tactile Brown Switch for Long-Time Typing
  • Aluminum Build That Won't Wobble - A tank-solid brushed aluminum board keeps every keystroke steady during intense sessions, unlike the flex you get from plastic-frame keyboards.
  • Swap Switches Without Soldering, Comfortable Out of the Box - The upgraded socket accepts almost any 3-pin or 5-pin switch, and the stock Brown switches give a soft tactile bump for all-day typing comfort.
  • Vibrant RGB for a True eSports Vibe - 20 preset lighting modes with adjustable brightness and flow speed give your desk the glow of a dedicated gaming rig.
  • Full Anti-Ghosting, Wide System Compatibility - 104 keys register accurately during rapid combos, and plug-and-play wired connection works across Windows and Mac with no drivers required.
  • Pro Software for Even Deeper Customization - Want to go beyond the onboard presets? The companion software lets you design custom RGB effects and program macros with your own keybindings.

A BCD store identifier takes the form of a globally unique identifier or GUID. A GUID has the following format:

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.
{xxxxxxxx-xxxx-xxxx-xxxx-xxxxxxxxxxxx}

“x” represents a hexadecimal digit. The table below lists and explains the well-known BCD store identifiers.

The identifiers in this table are represented by their friendly names instead of their GUID because they are well-known BCD store identifiers.
BCD Store IdentifiersMeaning/Notes
{bootmgr}Specify {bootmgr} to manage the Windows boot manager entry.
{fwbootmgr}Use this identifier on systems that implement the Extensible Firmware Interface (EFI) specification to specify the firmware boot manager entry.
{memdiag}Use {memdiag} to specify the memory diagnostic application entry.
{ntldr}Specifies a OS loader (Ntldr) that can be used to start operating systems earlier than Windows Vista.
{current}The {current} BCD store Identifier specifies a virtual identifier that corresponds to the operating system boot entry for the operating system that is currently running.
{default}Use {default} BCD store identifier to specify a virtual identifier that corresponds to the boot manager default application entry.
{ramdiskoptions}{ramdiskoptions} contains the additional options required by the boot manager for RAM disk devices.
{dbgsettings}{dbgsettings} contains the global debugger settings that any boot application entry can inherit.
{emssettings}The {emssettings} BCD store identifier contains the global Emergency Management Services settings that any boot application entry can inherit.
{badmemory}Contains the global RAM defect list that any boot application entry can inherit.
{globalsettings}The {globalsettings} BCD store identifier contains the collection of global settings that all boot application entries should inherit.
{bootloadersettings}Contains the collection of global settings that all Windows boot loader application entries should inherit.
{resumeloadersettings}This BCD store identifier contains the collection of global settings that all Windows resume should inherit from hibernation application entries.
{hypervisorsettings}{hypervisorsettings} contains the hypervisor settings that any OS loader entry can inherit.

BCDEdit Command-line Data Types

BCDEdit Command-line Data Types

The /set and /deletevalue BCDEdit commands require the <datatype> argument. <datatype> uniquely identifies both the data format and the meaning of the data value.

Before I explain the data types, it is important to show you the command you need to list them. To display the available BCDEdit command data types, run the command below.

BCDEdit /? TYPES

In the following subsections, I have explained the available BCDEDit data types.

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.
To learn about data type formats, see the next section – “BCDEdit Command-line Data Type Formats.”

BCDEDit BOOTMGR (Boot Manager) Data Types

The BOOTMGR (Boot Manager) data types apply only to entries for the boot manager.

In the table below, I have listed the part of the boot manager entry in column 1. Column 2 lists the data types and formats, while column 3 explains the data type.

In column two, the first part is the data type, while the text enclosed in () is the data type format. I have dedicated the next section of this article to explain the data type formats.
Boot entry section Boot Manager Data Types/FormatsMeaning/Notes
BootBOOTSEQUENCE (list)Defines the one-time boot sequence.
PERSISTBOOTSEQUENCE (bool)Enables persisting a boot sequence across multiple boots.
DEFAULT (id)Defines the default boot entry.
TIMEOUT (integer)Defines the boot manager time to wait, in seconds, before the boot manager selects a default entry.
ResumeRESUME (bool)Indicates that a resume operation should be attempted.
RESUMEOBJECT (id)Provides the identifier of the resume application object.
HIBERBOOT (bool)Indicates that a hiberboot resume should be attempted. This is used along with the RESUME setting and should not be modified.
DisplayDISPLAYBOOTMENU (bool)Enables the boot menu display.
DISPLAYORDER (list)Defines the boot manager display order list.
TOOLSDISPLAYORDER (list)Defines the boot manager tools display order list.

BCDEDit BOOTSECTOR (Boot Sector) Data Types

The BOOTSECTOR (Boot Sector) type applies to entries that contain bootsector in the form of a file. As of October 2022, there are no additional options for this type.

BCDEDit FWBOOTMGR (Firmware Boot Manager) Data Types

The FWBOOTMGR (Firmware Boot Manager) data types apply only to entries for the firmware boot manager.

What’s actually slowing this PC down?

Pick the symptom - the matching free tool is one click away.

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.

In the table below, I have listed the part of the boot manager entry in column 1. Column 2 lists the data types and formats, while column 3 explains the data type.

Firmware Boot Manager entry section Firmware Boot Manager Data Types/FormatsMeaning/Notes
BootBOOTSEQUENCE (list)Defines the one-time boot sequence.
DEFAULT (id)Defines the default boot entry.
TIMEOUT (integer)Defines the boot manager time to wait, in seconds.
DisplayDISPLAYORDER (list)Defines the boot manager display order list.

BCDEDit MEMDIAG (Memory Diagnostic Application) Data Types

The MEMDIAG (Memory Diagnostic Application) data types apply only to entries for memory diagnostic application entries.

In the table below, I have listed the part of the boot manager entry in column 1. Column 2 lists the data types and formats, while column 3 explains the data type.

Memory diagnostic entry sectionMemory diagnostic Data Types/FormatsMeaning/Notes
TestPASSCOUNT (integer)The number of iterations that will be run.
TESTMIXCan be BASIC or EXTENDED.
CACHEENABLE (boolean)Overrides the default cache settings of the testmix.

BCDEDit NTLDR (NTLDR-Based OS Loader) Data Types

The NTLDR data types apply to NTLDR-Based OS Loader. There is no additional options for this data type.

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.

BCDEDit OSLOADER (Windows OS Loader) Data Types

The OSLOADER (Windows OS Loader) data types apply only to Windows OS Loader entries. The table below explains the data types that apply to the Windows OS Loader.

The first column is the OS Loader section that the data type applies. Then, column 2 lists the data types while column 3 explains them.

Windows OS Loader entry sectionWindows OS Loader Data Types/FormatsMeaning/Notes
BootBOOTLOG (bool)Enables the system initialization log.
BOOTSTATUSPOLICYThis data type can be DisplayAllFailures, IgnoreAllFailures, IgnoreShutdownFailures, IgnoreBootFailures, IgnoreCheckpointFailures, DisplayShutdownFailures, DisplayBootFailures, or DisplayCheckpointFailures.
LASTKNOWNGOOD (bool)Enables boot to last known good configuration.
NOCRASHAUTOREBOOT (bool)Disables automatic restart on crash.
RESUMEOBJECT (id)Defines the identifier of the resume object that is associated with this operating system object.
SAFEBOOTCan be Minimal, Network or DsRepair
SAFEBOOTALTERNATESHELL (bool)Uses the alternate shell when booted into Safe mode.
SOS (bool)Displays additional boot information.
WINPE (bool)Enables the computer to boot to Windows PE.
DisplayBOOTUXDefines the graphics experience during boot. The values can be Disabled, Basic or Standard. (Defunct.)
BOOTMENUPOLICYDefines the type of boot menus the system will use. Can be Legacy or Standard.
OptionsADVANCEDOPTIONS (bool)Enables advanced options.
LOADOPTIONS (string)Defines any additional options that are not covered by other types.
OPTIONSEDIT (bool)Enables the options editor.
Processors and APICsCLUSTERMODEADDRESSING (integer)Defines the maximum number of processors to include in a single Advanced Programmable Interrupt Controller (APIC) cluster.
CONFIGFLAGS (integer)Specifies processor-specific configuration flags.
MAXPROC (bool)Uses only the specified number of processors.
ONECPU (bool)Forces only the boot CPU to be used.
RESTRICTAPICCLUSTER (integer)Defines the largest APIC cluster number to be used by the system.
USEPHYSICALDESTINATION (bool)Forces the use of the physical APIC.
USELEGACYAPICMODE (bool)Forces the use of legacy APIC mode even if the processors and chipset support extended APIC mode.
X2APICPOLICY (integer)Enables the use of extended APIC mode if the processors and chipset support extended APIC mode. Can be Enabled, Disabled or Default.
MAXGROUP (bool)Maximizes the number of groups created in group configuration.
GROUPAWARE (bool)Forces drivers to be aware of multiple groups in a multi-group environment.
GROUPSIZE (integer)Specifies the size of all processor groups. Must be an integer of power of 2.
Hardware Abstraction Layer (HAL) & KERNELHAL (string)Defines the file name for a private HAL.
HALBREAKPOINT (bool)Enables the special hardware abstraction layer (HAL) breakpoint.
KERNEL (string)Defines the file name for a private kernel.
USEPLATFORMCLOCK (bool)Forces the use of a platform clock source for the system’s performance counter.
FORCELEGACYPLATFORM(bool)Forces the OS to assume the presence of legacy PC devices like CMOS, keyboard controller etc.
VESA, PCI, VGA, and TPMUSEFIRMWAREPCISETTINGS (bool)Uses BIOS-configured Peripheral Component Interconnect (PCI) resources.
MSICan be Default or ForceDisable.
VGA (bool)Forces the use of the VGA display driver.
TPMBOOTENTROPYDetermines whether entropy is gathered from the trusted platform module (TPM) to help seed the random number generator in the operating system.
Can be Default, ForceDisable, or ForceEnable.
Debugging and PerformanceDBGTRANSPORT (string)Defines the file name for a private debugger transport.
DEBUG (bool)Enables kernel debugging.
PERFMEM (integer)Specifies the size (in megabytes) of the buffer to allocate for performance data logging.
MemoryINCREASEUSERVA (integer)Increases the amount of virtual address space that the user-mode processes can use, in MBs.
NOLOWMEM (bool)Disables the use of low memory.
NXEnables, disables, and configures Data Execution Prevention (DEP). DEP is a set of hardware and software technologies designed to prevent harmful code from running in protected memory locations.
You can use OptIn, OptOut, AlwaysOn or AlwaysOff.
PAEUse the PAE data type to enables or disables Physical Address Extension (PAE). When you enable PAE, the system loads the PAE version of the Windows kernel.
PAE can be Default, ForceEnable, ForceDisable.
REMOVEMEMORY (integer)Removes memory, in MBs, from the total available memory that the operating system can use.
Drivers and System RootDRIVERLOADFAILUREPOLICYCan be Fatal or UseErrorControl.
EMS (bool)Enables kernel Emergency Management Services.
OSDEVICE (device)Defines the device that contains the system root.
SYSTEMROOT (string)Defines the path to the system root.
HypervisorHYPERVISORLAUNCHTYPEControls the hypervisor launch type. Can be Off or Auto.
HYPERVISORDEBUG (bool)Enables hypervisor debugging.
HYPERVISORDEBUGTYPECan be SERIAL, 1394, or NET.
HYPERVISORDEBUGPORT (integer)Defines the serial port number for the serial debugger.
HYPERVISORBAUDRATE (integer)Defines the baud rate for the serial debugger.
HYPERVISORCHANNEL (integer)Defines the channel for the 1394 debugger.
HYPERVISORHOSTIP (integer)Defines the IPv4 address of the debugger host for the network debugger.
HYPERVISORHOSTPORT (integer)Defines the UDP port to communicate with on the debugger host for the network debugger.
HYPERVISORBUSPARAMS (string)Defines the PCI bus, device, and function numbers of the debugging device. For example, 1.5.0 describes the debugging device on bus 1, device 5, function 0.
HYPERVISORUSELARGEVTLB (bool)Increases virtual Translation Lookaside Buffer (TLB) size.
HYPERVISORIOMMUPOLICYControls the hypervisor Input Output Memory Management Unit (IOMMU) policy. Can be default, enable or disable.
Virtual Secure ModeVSMLAUNCHTYPEControls the Virtual Secure Mode launch type. Can be Off or Auto.

BCDEDit RESUME (Resume Loader) Data Types

The RESUME (Resume Loader) data types apply to entries for the resume loader. The table below explains the data types that apply to the Resume Loader.

The first column is the OS Loader section that the data type applies. Then, column 2 lists the data types while column 3 explains them.

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.
Resume Loader entry sectionResume Loader Data Types/FormatsMeaning/Notes
DisplayBOOTUXDefines the graphics experience during resume. Can be Disabled, Basic, or Standard. (Defunct.)
BOOTMENUPOLICYDefines the type of boot menus the system will use. Can be Legacy or Standard.

Hibernation fileFILEDEVICE (Device)Specifies the device containing the hibernation file.
FILEPATH (String)Specifies the path of the hibernation file.

OtherASSOCIATEDOSDEVICE (Device)Names the OS device associated with the hibernated OS. This is only useful in cases where the hibernation file is not stored on the OS device.
CUSTOMSETTINGS (Boolean)Allows resume loader to use custom settings.
PAE (Boolean)Indicates whether the hibernated OS was running with PAE enabled.

BCDEDit CUSTOMTYPES (Custom) Data Types

A custom data type (CUSTOMTYPES) identifies the data format and meaning of a value that is not represented by a friendly type name built in to BCDedit. Custom types are typically used to extend the functionality of BCD.

A custom type has the following format:

custom:0xXXXXXXXX 

The literal string “custom:” followed by an 8-digit hexadecimal number that encodes the format and meaning of the type.

A custom data type appears in the same parameter position as a friendly type name in a /set or /deletevalue command. For example:

BCDEDit /set {<id>} custom:0xXXXXXXXX <value>
Independent reader supportYour contribution helps us test, update, and keep practical guides available for everyone.Support on Ko-Fi

BCDEdit Command-line Data Type Formats

In the last section, I explained the data types you can use with the /set and /deletevalue BCDEdit commands. Some of the data types has specific data type formats they accept.

What’s actually slowing this PC down?

Pick the symptom - the matching free tool is one click away.

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.

For example, the WINPE Windows OS Loader Data type accepts the bool data format. Additionally, the bool data format accepts 1, ON, YES, TRUE as TRUE.

On the other hand, it also accepts 0, OFF, NO, FALSE as FALSE .

In this section, I’ll explain all the BCDEdit data type formats and the parameters they accept. Before I proceed, here is the command that lists all the data type formats I’ll explain shortly.

BCDEdit /? formats

In the table below, I have listed all the available data type formats, their command options and what they mean.

Free tools Windows power users keep installed

One-click scans. No signup required.

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.

BCDEDit bool Data Format

This data format represents a boolean value. The option can be either TRUE or FALSE.

However, you can also specify 1, ON, or YES instead of TRUE. In contrast, you can use 0, OFF, NO to replace FALSE.

As I hinted in this secrtion’s introduction, the WINPE Windows OS Loader Data type accepts the bool data format. In the last section, I explained that the WINPE data type enables the computer to boot to Windows PE.

So, if I want the running Windows to boot to WinPE, I will run the command below.

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.
BCDEDit /Set {current} WINPE TRUE

However, to stop the current OS booting into WinPE, run the command below.

BCDEDit /Set {current} WINPE FALSE

BCDEDit device Data Format

A device data format can be one of the following types:

BOOT
PARTITION=<drive>
HD_PARTITION=<drive>
FILE=[<parent>]<path>
RAMDISK=[<parent>]<path>,<optionsid>
<parent>]<path>,<locatecustom>
LOCATE[=<locatecustom>]

In the table below, I have explained the options above.

device Data FormatsMeaning/Notes
<drive>A drive letter with a colon and no trailing backslashes. For example, D:
<parent>This is a required option. You can be specify BOOT, LOCATE, or a drive letter with colon. The square brackets [] do not indicate that this is optional, but are a literal part of the syntax. So, when you specify the <parent> format, you must enclose it in [].
<path>A path to the file (or .wim file) from the root of the parent device.
<optionsid>The identifier to the device options entry that contains the system deployment image (SDI) options for the RAM disk. This is usually {ramdisksdioptions}.
<locatecustom>Supplies an optional element used to locate a device by looking for a specified path. The
default locate element for a device is its application path (systemroot for an osdevice).
Custom values must be specified using custom element syntax.

BCDEDit id Data Format

The BCDEDit id data format is an entry identifier. It refers to an entry in the boot configuration data store.

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.

To learn more about the id data format, run the command below.

BCDEDit /? ID

Some of the results of the commands are not shown in the screenshot below.

Also popular on Amazon
RedThunder K10 Wired Gaming Keyboard and Mouse and Wrist Rest Combo, RGB Backlit, Mechanical Feel Anti-ghosting Keyboard + 7D 7200 DPI Mice+Soft Leather Wrist Rest 3 in 1 PC Gamer Accessories(Black)
  • 【Professional Gaming Keyboard】The 104-key full-size keyboard has a standard layout with F-keys (function keys) and a numeric keypad, and 26 Anti-Ghosting keys allow you to press multiple keys simultaneously. The quality of the built-in steel plate of the keyboard is very strong and durable.
  • 【Professional gaming mouse】The mouse uses high-precision optical sensor, sensitivity is 7200DPI, 12000fps scan rate, 1000Hz tour detection rate, can withstand 40G acceleration and 400IPS tracking speed, can meet your fast browsing and game requirements.
  • 【Upgraded RGB Lighting Gaming Combo】All the keys of the keyboard, the light bar on the bottom side of the keyboard, and the RGB lights on the side of the mouse will glow. Your fingertips dance on the designed floating keycaps and click on the hyper-responsive mouse, accompanied by rainbow-like RGB lighting, allowing you to instantly enter the cool game state.
  • 【Perfect Ergonomic Computer Game Combo】The adjustable tripod keyboard makes your keys easier. The anti-slip material mouse that is more suitable for the hand can reduce your hand fatigue.Soft leather wrist rest made from smooth faux leather and memory foam for extra relaxation while gaming.
  • 【High-quality Game Combination】The curved ABS keycaps are exquisite in workmanship, the built-in steel plate of the keyboard base is sturdy and resistant to falling, the non-slip ABS material mouse has a better grip, and the soft leather wrist-rest filled with memory foam is more textured. High quality allows you to choose worry-free.
BCDEDit id Data Format

BCDEDit integer Data Format

An integer data format a 64-bit integer type. Some integer types can be set using numerated values.

BCDEDit integerlist Data Format

The integerlist data format is a list of one or more 64-bit integers, separated by spaces. This list should not be enclosed in quotation marks.

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.

BCDEDit list Data Format

A list data format is an entry identifier list. It contains one or more entry identifiers separated by spaces.

The list should not be enclosed in quotation marks.

BCDEDit string Data Format

A literal string, for example a file path. If it contains spaces, it should be surrounded by quotation marks (“”).

BCDEDit Command-line Examples

In this section I have discussed some examples with some applications of some of the topics I discussed in the preceding sections.

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.
Some of the commands in this section may delete important boot entries and stop your OS from starting. I recommend you run the commands on a test PC.
If I specify a boot ID in any command, the IDs are not real. To run the command on your PC, you need to get the identifiers of the boot entries on your PC by running “BCDEdit /enum ALL /v”

Example 1: Display the Current BCDEdit Global Debugger Settings

BCDEDit /dbgsettings

Example 2: Delete WinPE from Windows Boot Entry with BCDEdit

The following command deletes the Windows Preinstallation Environment (WinPE)
value from the current operating system boot entry:

BCDEdit /deletevalue winpe

The following command deletes the Windows PE value from the specified operating
system boot entry:

BCDEdit /deletevalue {cbd971bf-b7b8-4885-951a-fa03044f5d71} winpe

Example 2: Windows Boot Manager Display Order with BCDEdit

The following command sets two OS entries, and the NTLDR-based OS loader in
the boot manager display order:

BCDEdit /displayorder {802d5e32-0784-11da-bd33-000476eba25f} {cbd971bf-b7b8-4885-951a-fa03044f5d71} {ntldr}

Example 4: Enable Windows Remote Event Logging with BCDEdit

The following command enables remote event logging for the current Windows
operating system boot entry:

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.
BCDEdit /event ON

The following command disables remote event logging for the specified operating
system entry:

BCDEdit /event {cbd971bf-b7b8-4885-951a-fa03044f5d71} OFF

Example 5: Use BCDEdit to Enable Emergency Management Services in Windows Operating System

The following command enables Emergency Management Services for the current
operating system boot entry:

BCDEdit /ems ON

Example 6: Use BCDEdit to List Windows Operating System Boot Loader Entries

The following command lists all operating system loader boot entries:

BCDEdit /enum OSLOADER

However, you can list specific boot entries. For example, if you want to display only the boot manager entries, run the command below:

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.
BCDEdit /enum BOOTMGR

Alternatively, you can display only the default boot entry with this command.

BCDEdit /enum {default}

Finally, you can display information about a specific boot entry with the entry’s identifier. When I ran the “/enum OSLOADER” above, it displayed all operating system loader boot entries.

Each entry displays its identifier. You can display information about an entry with its identifier.

For example, to display the information about boot entry information with {0ee98279-2be9-11ec-a4f2-5414f3a8f4c0}, I will run the command below.

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.
BCDEdit /enum {0ee98279-2be9-11ec-a4f2-5414f3a8f4c0}
How To Use BCDEdit To List  In Windows Operating System Boot Entries

Finally, to display firmware boot entries, use the command below.

BCDEdit /enum firmware

Example 7: Export Windows BCD System Store

The following command exports the BCD system store to the specified file:

BCDEdit /export "C:\Data\BCD Backup"
The path you specify must exist. For example, the Data folder must exist in drive C:. If the folder does not exist, the BCD export store command will fail with the error message “The store export operation has failed. The system cannot find the path specified. Please DO NOT create “BCD Backup” as a folder as that is the BCD backup file.

Example 8: Import Windows BCD System Store

The following command imports the specified file into the system store.

BCDEdit /import "C:\Data\BCD Backup" /clean

Example 9: Check Hypervisorsettings With BCDEdit

The following command displays the current hypervisor settings:

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.
BCDEdit /hypervisorsettings

Example 10: Change Windows Boot Manager Timeout with BCDEdit

The following command sets the boot manager <timeout> to 30 seconds:

bcdedit /timeout 30

Example 11: Enable Safe Boot in Windows 10 and Windows 11 with BCDEdit

You can enable Safe Boot via MsConfig. However, you can enable safeboot in Windows 11 or Windows 10 by running the command below.

BCDEdit /set {current} SAFEBOOT Minimal

Example 12: List All Entries in the BCD Store with BCDEdit

To list all boot entries in the BCD store, run the command below:

BCDEdit /enum ALL /v
The /v argument is optional. Adding it displays the full identifies of all entry instead of displaying their well-known identifiers.

Frequently Asked Questions

1. What is BCDEdit used for?

BCDEdit is a command-line tool you can use to manage Boot Configuration Data (BCD) stores. The BCD store manages boot entries in a Windows computer.

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.
2. How do I run BCDEdit.EXE?

BCDEdit.EXE is a versatile Windows command line tool with many applications. To learn how to run the command, start by running the command that displays its parameters –

BCDEdit /?

Better still, you can read my comprehensive guide above.

3. What is BCDEdit /Set?

The BCDEdit /set command sets an entry option value in the boot configuration data store.

4. Does UEFI use BCD?

Yes. UEFI-based computer use BCD.

5. What causes Boot BCD error?

One of the common causes of BCD boot errors is corrupt or missing BCD store.

Conclusion

The BCDEdit command is a complex tool with so many applications. In this guide, I have covered everything you need to know about this versatile Windows command-line tool.

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.

I started with an overview of the command. Then, I discussed its syntax and explained all the options and their arguments.

Not only that, but I also explained the Well-known BCD Store Identifiers, explained BCDEdit data types and the formats. Finally, I shared some examples to help illustrate some applications of this tool.

I hope you found this ultimate guide helpful. If you did, click on “Yes” beside the “Was this page helpful” question below.

You may also express your thoughts and opinions by using the “Leave a Comment” form at the bottom of this page.

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.

Finally, if you enjoyed this article and want to learn more about Windows Command tools, visit our Windows Command Prompt Guides page.

Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon at the time of purchase will apply.