iTechGuides is reader-supported. When you buy through links on our site, we may earn an affiliate commission. As an Amazon Associate I earn from qualifying purchases. Learn more
For most six-bay UGREEN NASync DXP6800 Ultra owners, the practical starting point is a matched set of NAS-rated CMR SATA drives, with RAID 5 if one-drive fault tolerance is enough or RAID 6 if you want protection against two simultaneous drive failures. Choose RAID 10 when performance matters more than usable capacity. Before buying, confirm each drive’s exact manufacturer part number in UGREEN’s compatibility list; before creating a pool, back up any data on the selected drives because initialization formats them.
What drives should you choose for the DXP6800 Ultra?
Choose NAS-rated CMR SATA drives, ideally with the same nominal capacity and similar purchase age. CMR is the sensible default for an always-on RAID pool, but it does not guarantee compatibility or performance: verify the full part number against UGREEN’s current compatibility list for the exact DXP6800 Ultra model.
Prefer CMR over SMR
UGREEN recommends NAS-rated CMR drives for always-on storage and RAID. Its compatibility guidance warns: “SMR drives may exhibit unstable performance under continuous write operations or in RAID environments, potentially causing array degradation or data loss.” That makes SMR a poor choice for a RAID pool, even if a drive’s brand, capacity, and form factor otherwise appear suitable.
The Tool Desk
Outbyte Driver Updater FREEFix the driver behind crashes, sound loss and screen glitchesFind Drivers →Outbyte PC Repair FREEClear out junk files and repair common Windows errorsFree Scan →CMR is a drive-recording technology choice, not a promise that a particular disk will be fast, reliable, or supported. The compatibility check is separate: confirm the complete manufacturer part number, including capacity-specific suffixes, for this NAS model. A brand name or a product family alone is not enough to verify a particular drive.
Popular on Amazon
- Read Before You Buy — No Video Output: These adapters support charging and USB 2.0 data transfer, but cannot transmit video signals. Except for standard USB webcams (which use USB data only), they are not compatible with HDMI/DisplayPort cables, video-capable USB-C hubs, or docking stations with video output.
- Convert USB-A Ports to USB-C: Designed to connect USB-C earphones, cables, flash drives, card readers, and other USB-C accessories to standard USB-A ports. Plug-and-play with no drivers or software required.
- Aluminum Alloy Housing: Built with a sturdy aluminum alloy shell that aids in heat dissipation and protects against daily wear and scratches. Designed to maintain a stable and secure connection.
- Compact & Travel-Friendly: The ultra-compact design allows the adapter to stay plugged into your device without blocking adjacent ports or adding bulk, reducing wear and tear on your original USB ports.
- 12-Month Warranty: Backed by a 12-month manufacturer warranty for peace of mind. Designed to meet strict quality control standards for reliable everyday performance.
Match drive capacity and age where practical
In a conventional RAID layout, usable capacity is generally constrained by the smallest member drive. A larger drive mixed into a pool with smaller ones may therefore have capacity that the array cannot use. Matching capacity avoids that waste and makes the usable-space estimate easier to understand. UGREEN also discourages mixing new and old drives: a drive with more age or wear may be more likely to fail during the heavy workload of a rebuild.
Mixed capacities may work, but do not assume the extra space on larger members will become available. Use the smallest drive’s capacity in the formulas below, and check the options shown in UGOS Pro before committing to a layout. If you are buying a full set, a matched group from the same NAS-oriented product family, with the same nominal capacity and similar purchase age, is the clearest starting point.
Check the exact part number before ordering
- Open UGREEN’s compatibility list.
- Select the exact model, NASync DXP6800 Ultra, rather than a neighboring DXP model.
- Choose the HDD/SSD category and look up the complete manufacturer model number, including its capacity or other model suffixes.
- If the part number is not listed, treat it as unverified for this NAS. UGREEN says an unlisted component is not automatically incompatible, but its stability and performance are not guaranteed for that model.
For important files, favor a listed drive and keep a separate backup. A compatibility listing is not a substitute for a backup or a promise that a drive cannot fail. UGREEN lists Seagate, Western Digital, and Toshiba as drive-brand categories, but verify the exact part number rather than relying on the brand alone.
What should you know about the DXP6800 Ultra’s storage hardware?
The DXP6800 Ultra has six SATA bays that accept 2.5-inch or 3.5-inch drives, plus two M.2 2280 NVMe slots. UGREEN’s 2026 product specifications state a maximum of 32 TB per SATA drive and 8 TB per M.2 drive, for a headline maximum of 208 TB when all six SATA bays and both M.2 slots are filled to those capacities.
That 208 TB figure is not the usable capacity of a six-drive RAID pool: it adds the maximum published capacities across both kinds of slots. RAID redundancy reduces the space available for data, and the M.2 slots are separate from the SATA pool choices discussed here. UGREEN lists JBOD, Basic, RAID 0, RAID 1, RAID 5, RAID 6, and RAID 10 for the Ultra. Confirm the available choices in the current UGOS Pro interface when setting up storage.
Use the SATA bays to plan the main pool and its redundancy. The M.2 slots are an optional cache path, not additional members of the SATA RAID layouts described below. The published maximums are per-drive limits; actual usable space depends on the pool configuration, formatting, and system overhead.
Which RAID level makes sense for six drives?
For six matched drives, RAID 5 provides the most usable capacity among these three redundant layouts, RAID 6 tolerates two failed drives, and RAID 10 prioritizes mirrored redundancy and performance at roughly half of raw capacity. No RAID mode replaces a separate backup.
What’s actually slowing this PC down?
Pick the symptom - the matching free tool is one click away.
Also popular on Amazon
- 5-in-1 USB-C Hub: Experience comprehensive connectivity featuring a Power Delivery input, two USB-A 2.0 ports, a USB-A 3.0 port, and an HDMI port. (Note: The USB-C power delivery input port is only for connecting an external wall charger to power your laptop and cannot power peripheral devices.)
- 90W Pass-Through Charging: Achieve optimal charging with 90W pass-through power to your laptop, supported by a total input of 100W, with the hub reserving 10W for operational efficiency. (Note: Wall charger not included.)
- Quick Data Transfers: Accelerate your productivity with rapid data transfers using a high-speed 5Gbps USB 3.0 port and two 480Mbps USB 2.0 ports.
- 4K HDMI Display: Enhance your visual experience with a hub capable of delivering 4K resolution at 30Hz in both mirror and extend modes. Please note that this hub is compatible with MacBook (macOS 12 and newer), Windows 10 and 11, ChromeOS, and laptops equipped with DP Alt Mode and Power Delivery. Note: This device is not compatible with Linux.
- What You Get: Anker USB-C Hub (5-in-1, 4K HDMI), welcome guide, 18-month warranty, and our friendly customer service.
| RAID | Minimum drives | Approximate usable capacity | Drive failures tolerated | Write and rebuild considerations | Expansion behavior |
|---|---|---|---|---|---|
| RAID 5 | 3 | (drive count − 1) × smallest drive capacity | 1 | Single parity; UGREEN describes RAID 5 as a beginner-friendly balance. Rebuilds put the remaining drives under additional workload. | UGREEN says capacity can be increased by adding drives or replacing drives with larger ones; verify the specific option in UGOS Pro before migration. |
| RAID 6 | 4 | (drive count − 2) × smallest drive capacity | Up to 2 | Dual parity; it uses more capacity for redundancy and can incur more write overhead than RAID 5. | Not stated in UGREEN’s storage-mode guidance; check current UGOS Pro options before planning an expansion. |
| RAID 10 | 4, with an even drive count | Roughly half the total capacity, constrained by the smallest drive | One failed drive per mirror pair; two failures in the same pair can destroy the array | Combines mirroring and striping; choose it when performance and redundancy matter more than capacity efficiency. | UGREEN says capacity can be increased by adding drives or replacing drives with larger ones; verify the specific option in UGOS Pro before migration. |
For example, six equal 32 TB drives produce approximate nominal capacities of 160 TB for RAID 5, 128 TB for RAID 6, or 96 TB for RAID 10 before formatting and other storage overhead. These are formula-based estimates, not a guarantee of the space UGOS Pro will report. In each formula, “smallest drive” means that a larger member does not necessarily contribute its full capacity to the array.
Choose RAID 5 for capacity efficiency and one-drive protection
RAID 5 requires at least three drives and uses single parity. It is the capacity-efficient option when you accept that a second drive failure before the array is restored can put the pool at risk. UGREEN describes RAID 5 as its preferred beginner balance and recommends RAID 5 or RAID 6 for six-bay devices.
With six equal drives, the formula reserves capacity equivalent to one drive for parity. That leaves more room for data than RAID 6 or RAID 10, but RAID 5 protects against only one failed member at a time. If capacity is the priority and you can accept that limit, it is a reasonable starting point.
Choose RAID 6 when two-drive tolerance matters more
RAID 6 requires at least four drives and uses dual parity to tolerate up to two drive failures. It gives up the capacity of two drives, rather than one, compared with the approximate raw-capacity formula. That trade-off makes it the more conservative choice for a pool with large drives, higher-risk data, or a rebuild window during which you want protection from another drive failure.
Quick wins for a faster PC:
Fix the driver behind crashes, sound loss and screen glitchesFind Drivers →Clear out junk files and repair common Windows errorsFree Scan →The protection is specifically against up to two failed drives; it is not a substitute for backups, and it does not eliminate the need to monitor drive health. Its greater parity overhead can also make writes more demanding than RAID 5, so weigh that alongside the extra fault tolerance rather than treating the mode as universally better.
Choose RAID 10 when you accept the capacity cost
RAID 10 requires at least four drives and an even number of members. It stripes across mirrored pairs and uses roughly half of the total capacity. It can tolerate one failed drive in each mirror pair, but not two failures in the same pair; it is not equivalent to RAID 6’s protection against any two failed members.
That makes RAID 10 a workload-oriented choice: it is for users who value the performance characteristics of mirroring and striping, and who are willing to give up about half of the raw capacity for that layout. It is not the capacity-efficient choice for a six-bay NAS.
Also popular on Amazon
- Sleek 7-in-1 USB-C Hub: Features an HDMI port, two USB-A 3.0 ports, and a USB-C data port, each providing 5Gbps transfer speeds. It also includes a USB-C PD input port for charging up to 100W and dual SD and TF card slots, all in a compact design.
- Flawless 4K@60Hz Video with HDMI: Delivers exceptional clarity and smoothness with its 4K@60Hz HDMI port, making it ideal for high-definition presentations and entertainment. (Note: Only the HDMI port supports video projection; the USB-C port is for data transfer only.)
- Double Up on Efficiency: The two USB-A 3.0 ports and a USB-C port support a fast 5Gbps data rate, significantly boosting your transfer speeds and improving productivity.
- Fast and Reliable 85W Charging: Offers high-capacity, speedy charging for laptops up to 85W, so you spend less time tethered to an outlet and more time being productive.
- What You Get: Anker USB-C Hub (7-in-1), welcome guide, 18-month warranty, and our friendly customer service.
Plan by bay count, not just by RAID name
With two drives, RAID 1 is the redundant option; Basic is appropriate only if the data is already backed up elsewhere and you accept having no redundancy in the NAS. With three drives, RAID 5 is the one-drive-failure layout described here. At four drives, RAID 6 becomes available and trades roughly one additional drive’s worth of usable capacity compared with RAID 5 for tolerance of a second failure. With six drives, decide whether maximizing capacity (RAID 5), tolerating two failures (RAID 6), or prioritizing mirrored performance at roughly half capacity (RAID 10) best fits the pool.
UGREEN says RAID 5 and RAID 10 can increase capacity by adding drives or replacing members with larger ones. Do not assume every mode has the same expansion path: the cited storage-mode guidance does not state a RAID 6 expansion option. Check what the current UGOS Pro interface supports for your pool before buying drives for an expansion or starting a migration.
How do Basic, JBOD, RAID 0, and RAID 1 differ?
These modes are also listed for the DXP6800 Ultra, but they make different trade-offs. Basic and JBOD offer no redundancy, RAID 0 trades fault tolerance for striping, and RAID 1 mirrors two drives.
| Mode | How it uses drives | Failure protection | Practical use |
|---|---|---|---|
| Basic | One independent disk | None | Use only when the data is temporary, backed up elsewhere, or you accept the availability risk. |
| JBOD | Combines disks into one storage space | None; a disk failure loses data on that disk, and failure of the first disk can make the pool inaccessible | Use only when the data is temporary, backed up elsewhere, or you accept the availability risk. |
| RAID 0 | Stripes data across disks | None; failure of any drive loses the entire pool | A poor default for irreplaceable photos, documents, or business data. |
| RAID 1 | Mirrors two disks | One drive failure | A simple redundant layout for a two-drive start, with usable capacity equal to the smaller drive. |
For two drives, choose RAID 1 if you need redundancy; Basic is an option only if the data is already backed up and capacity efficiency matters more. With three drives, RAID 5 is the one-drive-failure option among the layouts covered here. At four drives, RAID 6 becomes available if you prefer two-drive tolerance over the extra capacity RAID 5 provides.
Basic and JBOD may look attractive if your goal is to combine disks without reserving capacity for parity or mirrors, but neither protects against drive failure. RAID 0 may offer striping, but the failure of any member loses the entire pool. For irreplaceable files, those modes should not be mistaken for safer or simpler versions of a redundant pool.
Recommended Free Tools
Can you use a hot spare?
UGOS Pro supports a hot spare with RAID 1, RAID 5, RAID 6, and RAID 10. UGREEN states that the spare must be at least as large as the smallest drive in the pool. A hot spare is an additional drive allocation, so plan its bay and capacity before deciding how many drives to put in the main pool.
On a six-bay unit, reserving a bay as a spare means fewer drives in the active pool, so compare that choice against using all bays for the selected RAID layout. A hot spare is not the same as a backup: it is part of a drive-failure response plan, while a separate backup protects against other causes of data loss.
Also popular on Amazon
- Dual Converters, Infinite Potential:Includes 2× USB C male to USB A female adapters and 2× USB A male to USB C female adapters. Perfect for a wide range of uses—tablets with Bluetooth keyboards, expand USB ports on macbook, and more. Two different converters for all your daily needs
- Next-Level 10Gbps & 3A Charging: No more slow 480Mbps, this usb to usb c adapter has a transfer speed of up to 10Gbps, allowing you to do more transferring in less time. This usb adapter fits both USB A and USB C charger, supporting up to 3A fast charging
- Upgraded Exquisite Craftsmanship: With an aluminum alloy housing and metal connector, the usbc to usb adapter is extremely durable and sturdy. Rigorously tested to withstand more than 10,000 times of plugging and unplugging, ensuring long-lasting performance
- Widely Compatible: Transform any USB-C port into a USB-A port and USB-A port into a USB-C port, and connect up a wide range of USB-C(including MacBook, iPad Pro/Air/Mini, iPhone models with USB C ports, Samsung Galaxy series, and Google Pixel series. ) and USB A devices(including external hard drives, phones, mice, printers, and more)
- Please Note: To reach 10Gbps speed, keep the cable under 3.3 ft. For USB A Male to USB C adapters, try flipping the USB C connector. USB C Male to USB A adapters support bidirectional 10Gbps transfer within 3.3 ft
How do you create a RAID pool in UGOS Pro?
Set up the pool and volume in the Storage app. Make your drive and RAID choices first, then review the configuration carefully: confirming Format initializes the selected drives and erases their existing data.
- Back up any data on the drives you intend to select. Do not proceed on the assumption that creating a pool preserves existing files.
- Open the Storage app and go to Storage > Storage Pool & Volume.
- Choose Create > Storage Pool.
- Select the intended drives and the RAID type. Confirm that the selected drive count meets the minimum for that RAID level.
- Optionally run the hard-drive test/check before continuing.
- Create a volume by setting its allocated capacity and selecting a file system.
- Review the configuration. If the selected drives, RAID type, and volume allocation are correct, click Create.
- Read the risk warning. To continue, choose Format, enter the administrator password, and submit.
- Wait for the storage pool and volume to finish initializing, then create folders.
UGREEN states that, when creating a storage pool, each hard drive must have at least 32 GB of available capacity. The initialization warning is the critical decision point: if a selected drive contains data you need, cancel and back it up before continuing.
Windows Errors? Fix Them Before They Spread
Repair common Windows errors and clear accumulated junk for a smoother, more stable PC - no reinstall needed.Free scan · no reinstallCrashes, No Sound, or Screen Glitches?
Random freezes, missing sound and display glitches usually trace back to one bad driver. Find and replace yours safely.Free scan · under a minuteBefore confirming, check that you selected only the intended members and that the RAID type and volume allocation match your plan. The format step is destructive to the selected drives. If you are unsure whether a disk contains needed files, stop rather than relying on RAID creation to preserve them. Once initialization finishes, create folders and begin using the volume.
Can you add an M.2 SSD cache later?
The two M.2 NVMe 2280 slots can support an optional cache in UGOS Pro; an SSD cache is not required to create a SATA RAID pool. UGREEN documents read-only cache with at least one SSD and read-write cache with at least two SSDs. Check the exact SSD model in the compatibility list, and treat caching as a workload-dependent option rather than a way to protect data or replace the main pool.
Because cache is optional, it does not need to be part of the initial drive purchase unless your workload calls for it. The published supported cache modes specify the minimum SSD count, not a universal speed improvement. Verify the SSD’s exact model number just as you would for an HDD, and do not count the cache as a backup or as a replacement for RAID redundancy.
Independent reader supportYour contribution helps us test, update, and keep practical guides available for everyone.What happens if a drive fails?
The answer depends on the RAID layout: Basic, JBOD, and RAID 0 have no redundancy; RAID 1, RAID 5, RAID 6, and RAID 10 have the specific failure limits described above. RAID can help keep a pool available through some drive failures, but it does not protect against every cause of data loss. Keep a separate backup and monitor drive health, as UGREEN advises.
RAID 5 has a one-drive failure limit, RAID 6 can tolerate up to two failed drives, and RAID 10’s tolerance depends on which mirrored pair loses a member. If a failure occurs, the state of the pool and its options depend on the selected layout; do not assume that every array can survive another failure during a rebuild. UGREEN cautions that older drives may be more vulnerable under rebuild workload, which is another reason to monitor health and keep backups current.
Also popular on Amazon
- 5-in-1 Connectivity: Equipped with a 4K HDMI port, a 5 Gbps USB-C data port, two 5 Gbps USB-A ports, and a USB C 100W PD-IN port. Note: The USB C 100W PD-IN port supports only charging and does not support data transfer devices such as headphones or speakers.
- Powerful Pass-Through Charging: Supports up to 85W pass-through charging so you can power up your laptop while you use the hub. Note: Pass-through charging requires a charger (not included). Note: To achieve full power for iPad, we recommend using a 45W wall charger.
- Transfer Files in Seconds: Move files to and from your laptop at speeds of up to 5 Gbps via the USB-C and USB-A data ports. Note: The USB C 5Gbps Data port does not support video output.
- HD Display: Connect to the HDMI port to stream or mirror content to an external monitor in resolutions of up to 4K@30Hz. Note: The USB-C ports do not support video output.
- What You Get: Anker 332 USB-C Hub (5-in-1), welcome guide, our worry-free 18-month warranty, and friendly customer service.
Frequently Asked Questions
Does the DXP6800 Ultra’s 208 TB maximum mean I can store 208 TB in RAID?
No. UGREEN’s 2026 headline figure adds the maximum published capacity of six SATA drives and two M.2 drives; it is not a RAID usable-capacity figure. A SATA RAID pool’s usable space depends on its RAID level and smallest member drive, while the M.2 slots are separate.
Do all drives in a storage pool need to have at least 32 GB?
UGREEN’s Storage guidance says each hard drive must have at least 32 GB of available capacity when creating a storage pool. That is a minimum available-capacity requirement, not a recommended drive size.
Can an unlisted drive still work in the DXP6800 Ultra?
UGREEN says an unlisted component is not automatically incompatible, but it has not been verified for that exact NAS model and its stability or performance is not guaranteed. For a pool holding important data, choosing an exact listed part number reduces that uncertainty.
Free tools Windows power users keep installed
One-click scans. No signup required.
Should I use an SSD cache instead of RAID?
No. Cache is an optional workload-dependent feature, while RAID defines how the main pool uses its drives and handles certain drive failures. UGREEN documents read-only cache with one SSD or more and read-write cache with at least two; neither cache mode replaces a separate backup.
Can I mix drive sizes in the DXP6800 Ultra?
Mixed capacities may work, but do not assume that larger drives’ extra space will be usable in a conventional RAID pool. Capacity is generally based on the smallest member: RAID 5 uses approximately (drive count − 1) × smallest drive capacity, RAID 6 uses (drive count − 2) × smallest drive capacity, and RAID 10 is constrained by the smallest drive. Confirm the available setup options in UGOS Pro.
Do I need CMR drives for RAID?
UGREEN recommends NAS-rated CMR drives for always-on storage and RAID, and warns that SMR drives may have unstable performance in continuous-write or RAID environments. CMR is the recommended default, but check the exact drive part number in UGREEN’s compatibility list.
What RAID should I use on a six-bay NAS?
Choose RAID 5 if capacity efficiency and tolerance of one failed drive are your priorities. Choose RAID 6 if you want protection against up to two failed drives and accept less usable capacity. Choose RAID 10 if you prioritize its performance-oriented mirrored layout and accept roughly half of raw capacity.
Do these 3 things before closing this tab:
1Clear out junk files and repair common Windows errors2Scan for outdated or missing drivers - takes under a minute3Repair Windows errors before they cause bigger problemsWill creating a storage pool erase the drives?
Yes. The UGOS Pro setup path asks you to choose Format, and initialization formats the selected drives. Back up anything you need before confirming; if you are unsure whether a selected drive contains important files, cancel and check first.
Can I add drives or larger drives to a RAID pool later?
UGREEN states that RAID 5 and RAID 10 support capacity increases by adding drives or replacing drives with larger ones. Check the current UGOS Pro options for your particular pool before planning a migration; the cited storage-mode guidance does not state the same expansion options for RAID 6.
The Bottom Line
Bottom line: Start with matched NAS-rated CMR drives whose exact part numbers appear in UGREEN’s DXP6800 Ultra compatibility list. For six bays, use RAID 5 when capacity and one-drive tolerance are enough, RAID 6 when two-drive tolerance matters more, or RAID 10 when you prioritize its mirrored performance characteristics and accept roughly half-capacity efficiency. Back up first: creating the pool and confirming Format initializes the selected drives.
Quick Recap
Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon at the time of purchase will apply.