You can meet a 98% uptime target on AWS by defining availability around what customers can actually do, measuring it consistently, and reducing the time to detect and recover from failures. The 98% figure is normally your workload’s service level objective (SLO), not a universal end-to-end guarantee from AWS. AWS service-level agreements (SLAs) cover specific services under their own terms; they do not automatically guarantee that a multi-service application will be available.

What does 98% uptime allow?

For an assumed 30-day month of 43,200 minutes, 98% availability allows 864 minutes of unavailability: 14 hours and 24 minutes. This is a calculation from the stated 30-day assumption, not an AWS-published statistic. A 28-, 29-, or 31-day calendar month has a different time-based allowance.

You can also define availability by requests rather than elapsed time. In that case, 98% means at least 98% of valid requests meet your success criteria during the measurement window; at most 2% may fail those criteria. Do not convert a request-based target into hours of downtime.

AWS defines availability as the percentage of time a workload is available for use, but the owner must define what “available” means for the workload. A server returning a response is not enough if a customer cannot complete the essential task, or if the response arrives too late to be useful. AWS’s availability guidance discusses measuring workload availability around its functions and customer experience.

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.
#1 Best Overall
Sale
CyberPower ST425 Standby UPS Battery Backup and Surge Protector
  • 425VA/260W Standby Uninterruptible Power Supply (UPS): Uses simulated sine wave output to provide battery backup power and to safeguard home office, home entertainment including computers, gaming consoles, and broadband routers
  • 8 NEMA 5-15R OUTLETS: Four battery backup & surge protected outlets; Four surge protected outlets; INPUT: NEMA 5-15P right angle, 45 degree offset plug with five foot power cord
  • ADDITIONAL FEATURES: LED status light indicates Power-On and Wiring Fault, transformer-spaced outlets
  • GREENPOWER UPS HIGH EFFICIENCY DESIGN: Reduces power consumption by utilizing a compact charger and power inverter to create an ultra-efficient backup power system for home and office use
  • 3-YEAR WARRANTY – INCLUDING THE BATTERY; 75K USD Connected Equipment Guarantee; UL SAFETY CERTIFIED: Product has been tested in a UL certified lab and listed with UL as meeting or exceeding safety standards

Separate the SLI, SLO, and AWS SLA

Term What it means Example
SLI The service level indicator: the measured signal. Successful valid customer requests divided by all valid customer requests.
SLO The service level objective: the target and measurement window you choose. At least 98% of valid requests succeed over a calendar month.
SLA A contractual service-level agreement from a provider, with defined coverage and remedies. An AWS service commitment with its own availability calculation, exclusions, and possible service credits.

Your application’s SLO is an engineering target you select and measure. An AWS service SLA applies only to the named service and the conditions in its current terms. An AWS component meeting its SLA does not prove that your application met its SLO: your application may also depend on other AWS services, third parties, code, configuration, and client network paths.

Choose an SLI that matches the customer experience and use one coherent definition throughout dashboards and reports. Amazon CloudWatch SLOs support period-based objectives, such as good periods divided by total periods, and request-based objectives, such as good requests divided by total requests. The documentation also describes error-budget reporting and composite SLOs that combine two to 20 operations. See Amazon CloudWatch SLO documentation for the current feature details.

Define what counts as available for your workload

Start with the critical customer journey, not the infrastructure diagram. For each operation that matters, specify valid traffic, the expected result, and an acceptable response-time threshold. A request that succeeds only after the client has timed out may be a failure from the customer’s perspective, even if a server eventually returns success.

  • Identify the key operation or journey, such as signing in, placing an order, or retrieving a record.
  • Define which requests are valid for measurement and which outcomes count as good, failed, or too slow.
  • Decide how to treat scheduled maintenance, periods with no traffic, client errors, and partially working features. Document the choice rather than silently inheriting an AWS service’s SLA rules.
  • Measure from both the service side and a client perspective where appropriate. Client-side canaries can expose failures that internal health checks miss.

For a period-based SLI, define the period length and the condition for a good period—for example, whether a one-minute period is good only when the critical operation works within the latency limit. For a request-based SLI, define the request population and success condition. These approaches answer different questions; avoid combining them as if their denominators were interchangeable.

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.

Set the 98% SLO and track its error budget

Write the target together with its SLI and window, such as “98% of valid checkout requests succeed during each calendar month.” A bare “98% uptime” target is ambiguous if it does not say what is measured, over what period, and what counts as unavailable.

Rank #2
Sale
APC BX1500M UPS Battery Backup & Surge Protector for Computers, Electronics
  • 1500VA / 900W RELIABLE BACKUP POWER: The highest VA capacity available for home use; delivers short-term battery power to keep essential devices powered during blackouts, surges, and unexpected power interruptions
  • TEN PROTECTED OUTLETS: Power your entire setup with 5 battery backup outlets for essential devices, and 5 surge-only outlets for peripherals. Plus built-in coaxial and Ethernet surge protection for added peace of mind
  • AUTOMATIC VOLTAGE REGULATION (AVR): Corrects low voltage brownouts (88V+) and surges (+/-13%) without draining battery. Boosts or trims to stable 120V. Extends runtime for blackouts; Active PFC compatible for gaming PCs
  • REPLACEABLE BATTERY & ENERGY STAR UPS: User-replaceable battery (APCRBC124, sold separately) for zero-downtime swaps. ENERGY STAR certified for 92%+ efficiency, cutting energy costs vs standard UPS units
  • LCD DISPLAY PANEL: Features an intuitive LCD screen that displays real-time status information including battery charge level, estimated runtime, load capacity, and input voltage for easy monitoring of your power protection system

The error budget is the amount of non-compliance the target permits in its measurement window. For a 98% request-based objective, up to 2% of valid requests may fail the defined success criteria. For a 30-day time-based objective, the corresponding allowance is 14 hours and 24 minutes. Track budget consumed as well as whether the target was met, so an incident early in the period is visible before the window closes.

AWS describes an error budget as the amount of requests that can be non-compliant while the application still meets its SLO. That request-based wording applies to that definition; for a period-based SLO, track the budget using the period-based SLI’s own units. CloudWatch’s SLO documentation explains both objective types and error-budget reports.

Map dependencies before adding redundancy

List everything needed to complete the measured customer operation: application components, data stores, identity, DNS, network paths, third-party APIs, and operational processes. Mark single points of failure and note which components are hard dependencies. If a critical dependency is unavailable, determine whether the customer operation can still succeed in a degraded mode or fails outright.

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.

For hard dependencies, AWS illustrates that the invoking workload’s availability is the product of component availabilities. This model shows why several individually reliable components do not automatically make a highly available end-to-end service. The multiplication is a theoretical model, not a substitute for measuring the workload, and correlated failures can invalidate assumptions of independence.

Redundant components can improve theoretical availability when they fail independently and failover works. A second instance, Availability Zone, or region will not help as intended if both paths share a failure mode, if capacity is insufficient, or if health detection and recovery are not reliable.

Rank #3
Sale
CyberPower CP1500PFCLCD PFC Sinewave UPS Battery Backup and Surge Protector
  • 1500VA/1000W PFC Sinewave Uninterruptible Power Supply (UPS): Uses sine wave output to provide battery backup power for Active PFC & conventional power supplies; Safeguards computers, workstations, network devices, and telecom equipment
  • 12 NEMA 5-15R OUTLETS: 6 battery backup & surge protected outlets, 6 surge protected outlets; INPUT: NEMA 5-15P right angle, 45 degree offset plug with 5 foot power cord; 2 USB charge ports (1 Type-A, 1 Type-C) quickly charge phones and tablets
  • MULTIFUNCTION, COLOR LCD PANEL: Displays immediate, detailed information on battery and power conditions; Color display alerts users to potential issues before they can affect critical equipment and cause downtime; Screen tilts up to 22 degrees
  • AUTOMATIC VOLTAGE REGULATION (AVR): Corrects minor power fluctuations without switching to battery power; UL SAFETY CERTIFIED: Product has been tested in a UL certified lab and listed with UL as meeting or exceeding safety standards
  • 3-YEAR WARRANTY – INCLUDING THE BATTERY; $500,000 Connected Equipment Guarantee; FREE PowerPanel Management Software (Download)

Improve detection, recovery, and resilience

Detect user-impacting failures

Alert on the SLI that represents customer impact, not only on infrastructure signals such as instance state. Combine service-side telemetry with health checks or client-side canaries where they add coverage. Watch latency as well as outright errors: a slow response can be functionally unavailable to a client with a fixed timeout. Look for partial failures, such as a working home page but a failing checkout operation.

Make recovery repeatable

Use tested runbooks, safe automated recovery, and incident practice to reduce time to detect and restore service. A health check should reflect whether the workload can perform its critical operation, not merely whether a process is running. Test the recovery path regularly; an untested failover mechanism is an assumption, not evidence of resilience.

Free tools Windows power users keep installed

One-click scans. No signup required.

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.

Add redundancy for a defined failure domain

Choose redundancy based on the failures you need to tolerate. Multi-AZ deployment addresses a different failure domain from an instance-level replacement or a multi-region design. Plan for capacity, failover behavior, data consistency, health detection, and the operating work required to keep the design safe. Set and test recovery objectives, including recovery time and data loss tolerance where relevant.

AWS cautions that higher availability typically increases cost and calls for stronger testing, validation, and operational practices. Its Reliability Pillar availability guidance uses 99.999% as an explanatory “five nines” example, not as a universal AWS workload promise. A more demanding target is useful only when it matches the business need and the system can operate it reliably.

Independent reader supportYour contribution helps us test, update, and keep practical guides available for everyone.Support on Ko-Fi

Understand what AWS service SLAs cover

Service SLAs are useful for understanding AWS’s contractual commitments for particular dependencies, but their scope and measurement are service-specific. The figures below are examples from AWS’s official SLA pages reviewed on October 4, 2026; check the current terms before relying on them because service terms can change.

Rank #4
Sale
CyberPower EC850LCD Ecologic UPS Battery Backup and Surge Protector
  • 12 NEMA 5-15R OUTLETS: Six battery backup & surge protected outlets; Six surge protected outlets (Three ECO controlled); INPUT: NEMA 5-15P right angle, 45 degree offset plug with five foot power cord
  • MULTIFUNCTION LCD PANEL: Displays immediate, detailed information on battery and power conditions
  • ECO MODE: When the UPS detects a computer is off or in sleep mode, it will automatically turn off power to computer peripherals connected to ECO mode outlets, reducing power usage and lowering energy costs
  • 3-YEAR WARRANTY – INCLUDING THE BATTERY; $100,000 Connected Equipment Guarantee and FREE PowerPanel Personal Edition Management Software (Download)

Amazon EC2

The Amazon Compute Service Level Agreement states a 99.99% regional commitment when all running instances are deployed concurrently across two or more Availability Zones in a region, with a stated alternative for a region that has only one Availability Zone. It also states a 99.5% commitment for a single EC2 instance. The page specifies service-credit tiers and exclusions. These figures apply to the SLA’s defined EC2 scope and conditions, not to an arbitrary application built from multiple services.

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.

Amazon S3

The Amazon S3 Service Level Agreement uses per-request-type error rates over five-minute intervals to calculate uptime and lists different credit tiers by storage class. For specified S3 Standard, S3 Express One Zone, Glacier Flexible Retrieval, Glacier Deep Archive, and other requests, the listed tiers begin below 99.9%, then below 99%, then below 95%. For Intelligent-Tiering, Standard-IA, One Zone-IA, and Glacier Instant Retrieval, listed tiers begin below 99%, then below 98%, then below 95%. The SLA also sets exclusions and a claim deadline.

These service-level thresholds are not your application’s SLO. A workload result of 98% does not by itself establish eligibility for an AWS service credit; the applicable service, calculation, exclusions, and claim requirements control. Credits are subject to the exact SLA and are not necessarily cash refunds or compensation for business impact.

Review results and adjust the design

Review SLO attainment and error-budget use alongside incidents, recovery times, user-facing latency, and the cost and operating complexity of resilience measures. If the target is missed, identify whether the cause was a dependency, a detection gap, a slow recovery, or a failure mode the design does not isolate. If the target is comfortably exceeded, consider whether the reliability margin is worth its cost or whether the objective should better reflect customer needs.

The measure of success is the workload’s customer-visible result over the SLO window. Architecture diagrams, component SLAs, and redundancy are inputs to that outcome—not substitutes for observing it.

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.

Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon at the time of purchase will apply.