Facebook made data-center hardware “open” by publishing designs—including technical specifications and mechanical CAD files—for others to use, test, and improve. Announced on April 7, 2011, the Open Compute Project (OCP) applied open-source collaboration to servers and facility infrastructure, not just software.
Why Facebook opened its hardware designs
As Facebook’s service grew, the company needed data-center infrastructure that could scale without wasting energy or capital. Its custom data center in Prineville, Oregon, became the basis for an effort to share the engineering behind that infrastructure.
At the OCP launch, Facebook vice president of technical operations Jonathan Heiliger said, “We think it’s time to demystify the biggest capital expense of an online business — the infrastructure.” The idea was to let other organizations inspect and adapt designs rather than keep the work proprietary.
What Facebook released on April 7, 2011
Facebook announced OCP on April 7, 2011, and shared designs covering servers, power, racks, batteries, and data-center facilities. The released material included technical specifications and mechanical CAD files. OCP was intended as a collaborative project: participants could use the designs, test them, and suggest changes.
Recommended Free Tools
#1 Best Overall
- 【Wide Application】 XOOL M6 Rack Mount Screw Kit is great for mounting your rack server cabinets, server shelves, A/V device enclosures, and more. These M6 cage nuts and screws are universally compatible with all square-hole racks and cabinets. Easily mount your equipment using this convenient kit, which comes with everything you'll need to get the job done. These self-locking cable ties are perfect for computer, appliance and electronic cord organization, wire management and storage.
- 【Superb Quality】 The cage nuts and screws is made of high quality Carbon Steel. The Carbon Steel material features strength and offers good corrosion resistance in bad environment like high temperature, cold weather, and high humidity areas. They have superior rust resistance and the excellent of oxidation resistance, which can ensure long time using and prolong screws and nuts lifespan. Wear resistant feature make the cage nuts and screws more durable and solid.
- 【Standard Metric】 Our M6 screws and cage nuts accord with standardized metric system. And the average error is less than 0.01mm. The screw thread is very sharp, clean and accurate without burr. The compact and force uniform screw thread is not easy to out of shape and slid in the process of rolling and installation. The deep and clear flat cross head can make your working more easily and improve your work efficiency.
- 【Safety and Eco-Friendly】 XOOL M6 screws and cage nuts use high quality Carbon Steel raw material, which is environmental protection and non-poisonous. In the process of using, there are no toxic substances releasing, which will ensure your safety. After heat treating, carbon steel has good mechanical properties of ductility, hardness, yield strength, or impact resistance.
- 【Thoughtful Design】 We add self-locking Nylon cable ties on our package. The CABLE TIES is good for home, office, garage, workshop and more. And the screw is very easy to insert with hand.
Meta’s engineering team described the invitation this way: “We want you to tell us where we didn’t get it right and suggest how we could improve.” It also said, “The ultimate goal of the Open Compute Project, however, is to spark a collaborative dialogue.”
What changed in the physical design
The 2011 designs rethought power delivery, server layout, and cooling. Rather than simply publish a conventional server blueprint, Facebook described a set of choices intended to remove inefficiencies across the facility and the hardware inside it.
Rank #2
- Accurate & Durable Design:Our M6 screws and cage nuts are manufactured to strict metric standards with an average tolerance of less than 0.01 mm for accurate fit and reliable performance. The threads are sharp, clean, and burr-free, ensuring smooth installation. The compact, evenly distributed thread design resists deformation and slipping during fastening. A deep, well-defined Phillips head allows for easier operation and improved work efficiency.
- Heavy-Duty & Long-Lasting:Constructed from premium carbon steel with a protective black nickel coating to resist rust and oxidation. Designed to withstand high temperatures, cold weather, and other harsh conditions for reliable, long-term performance.
- Clean & Professional Look:Finished in sleek black nickel to match most rack systems, delivering a clean, organized, and professional appearance inside your cabinet.
- Wide Application:Perfect for server cabinets, rack shelves, and A/V enclosures. Compatible with all standard square-hole racks, this M6 cage nut and screw kit provides secure installation hardware along with durable self-locking cable ties for clean and organized wire management.
- 50-Pack Complete Set – Comes with 50 cage nuts, 50 mounting screws, and 50 black washers. Packaged in a sturdy small box to keep everything organized and easy to store.
Power distribution and simplified components
The Prineville design used 480-volt power distribution and a direct power interface for servers. Facebook also removed nonessential parts from the equipment. The engineering goal was to reduce conversion losses and avoid spending energy on components that did not contribute to the computing work.
A taller chassis and lower fan-power demand
The Open Compute server chassis was 1.5U tall, or 2.63 inches. Facebook said the larger space allowed larger 60 mm fans and heat sinks. In its 2011 figures, fan power accounted for 2–4% of server power, compared with 10–20% for a standard server. Those are Facebook’s reported figures for the designs it described, not a universal measurement for every server.
The Tool Desk
Outbyte PC Repair FREEClear out junk files and repair common Windows errorsFree Scan →Outbyte Driver Updater FREEFix the driver behind crashes, sound loss and screen glitchesFind Drivers →Rank #3
- 【UNIVERSAL 19-INCH RACK COMPATIBILITY】No more ill-fitting hardware! Our M6 x 16mm fasteners fit all standard 19-inch SERVER RACKS, network cabinets and data centers—seamless lock-in, zero size guesswork, no return risks for mismatched parts. Perfect for your rack mount setup
- 【DURABLE BLACK ZINC-PLATED BUILD】Fight mild rust and stripping! Our RACK MOUNT HARDWARE features thick BLACK ZINC PLATING on carbon steel—resists wear, bending and indoor/semi-outdoor corrosion for 2+ years. Sturdier than generic flimsy fasteners
- 【50-PACK ALL-IN-ONE CAGE NUTS KIT】No mid-install part runs! Our complete 50-pack of CAGE NUTS includes matching M6 screws, washers + FREE self-locking cable ties—exact parts for rack/cabinet builds, no extra hardware store trips
- 【TOOL-FREE SNAP-ON EASY INSTALL】Skip complex tools and slow builds! Our RACK MOUNT SCREWS pair with snap-on cage nuts (hand-installed)—twist in with a basic Phillips driver, no stripping. Finish your rack setup in 10-15 mins, even for first-timers
- 【MULTI-USE RACK ACCESSORY HARDWARE】Max out your setup versatility! This hardware works for all NETWORK AND SERVER RACK ACCESSORIES—small business racks, office cabinets, home labs, audio racks. Washers prevent scratches, cable ties tidy wiring
Facility cooling and heat reuse
The data-center design used hot aisles and reused heat rather than treating server cooling as a separate problem from facility design. The broader approach linked server airflow, cooling equipment, and the building layout.
What the reported energy and cost figures mean
Facebook reported that the Prineville facility achieved a power usage effectiveness (PUE) of 1.07, compared with 1.5 at its existing facilities. PUE compares total data-center energy use with the energy delivered to IT equipment; a lower value means less overhead energy for cooling and other facility needs.
Rank #4
- COMPLETE M6 RACK SCREWS KIT:Includes 45 square rack cage nuts, 45 rack mounting screws and 45 black washers stored in a plastic storage box for easy organization and quick access
- DURABLE CARBON STEEL WITH BLACK NICKEL PLATING:Rack screws and cage nuts are built of carbon steel with black nickel coating to deliver excellent oxidation, rust, corrosion and wear resistance for long-term use in high and low temperature environments
- PRECISE SHARP THREADS FOR SAFE INSTALLATION:Server rack mounting hardware features deep sharp threads and smooth burr-free surface for secure, safe installation of rack and cabinet equipment
- UNIVERSAL COMPATIBILITY FOR SQUARE-HOLE RACKS:M6 x 16mm rack screws fit standard 10mm square-hole racks and cabinets; ideal for mounting servers, switches, routers and A/V equipment in data centers and workspaces
- TIGHT TOLERANCE MANUFACTURING:Conforms to metric standard with less than 0.01mm average error; compact thread structure ensures tight fit, uniform force distribution and resistance against deformation and slipping
Facebook also reported 38% less energy for the same work and 24% lower data-center infrastructure cost in 2011. These were company-reported results for its facilities and designs. They show the gains Facebook said it achieved, but they are not a like-for-like total-cost study covering every OCP deployment or a guarantee that another operator would see the same savings.
Independent reader supportYour contribution helps us test, update, and keep practical guides available for everyone.How the project expanded beyond the launch designs
Compute
Facebook published motherboard designs for both AMD and Intel processors. Later OCP work included doubled-density compute designs, extending the project from the original server concepts toward denser configurations.
Quick wins for a faster PC:
Clear out junk files and repair common Windows errorsFree Scan →Scan for outdated or missing drivers - takes under a minuteDriver Scan →Repair Windows errors before they cause bigger problemsFix Now →Best Value
- Pro Grade – Here is our new Black M6 Rack Screws and Cage Nuts Set [25 x Server Rack Screws, 25 x Cage Rack Nuts, 25 x Washers] used for mounting server racks, enclosures, cabinets, and more.
- Strong & Durable – Our Rack Cage Nuts & Relay Rack Screws for server rack have a high-grade carbon steel construction to prevent stripping. The M6 Cage Nuts and Bolts have also been coated in zinc chromate plating for resistance from corrosion.
- Wide application – Our rack screws & nuts are universally compatible with all square hole racks & cabinets. This makes the rack cage nuts and screws suitable for mounting all server rack hardware, including rack server cabinets, server shelves, A/V device enclosures, and other server mounting procedures.
- Easy to install – Our server rack screws and clip nuts have a Phillip’s truss-head with self-guiding pilot points to allow you to install in no time. The rackmount screws and nuts thread are extra sharp, clean & accurate, offering a smooth & satisfying installation process.
- Essential Bundle – Our Cage nuts & screws m6 set includes all the essential parts for mounting your server equipment. Pack not only includes screws & cage nuts; we have also thrown in additional heavy-duty washers to reduce any marks or scratches when installed. We truly believe our server rack nuts and bolts set is the best in the marketplace and we stand by that. If our cage nut set starts driving you nuts, we’ll FULLY REFUND YOU. So, click “Add to Cart” now and buy with confidence.
Storage
A storage platform described in 2011 could support up to 50 hard drives in a fully loaded node. Facebook initially released this storage design for community feedback while it was still being tested, so it should not be read as a finished or universally deployed product specification.
Which companies helped build the ecosystem
Early participants included AMD, Dell, HP, Intel, and Synnex. Their involvement helped bring processor, server, and supply-chain expertise into a project whose designs were meant to be examined and iterated on by more than Facebook alone.
By 2015, Facebook described OCP as covering every major physical component of its data-center stack and said the effort had saved $2 billion in infrastructure costs over three years. That figure is Facebook’s 2015 account of its own infrastructure savings, not a measured industry-wide total.
What OCP openness does—and does not—mean
OCP made design information available for collaboration, but openness does not mean every component is interchangeable or that every design is suitable for every facility. Specifications evolved over time, and the 2011 designs are historical examples rather than current consumer products. The documented case is about enterprise data centers and hardware suppliers; it does not establish consumer adoption.
What’s actually slowing this PC down?
Pick the symptom - the matching free tool is one click away.
The strongest supported benefits are the efficiency and cost improvements Facebook reported for its own facilities, plus a process for sharing and improving physical infrastructure designs. The figures should be understood in that context, rather than as a blanket promise for any organization adopting an OCP design.
Quick Recap
Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon at the time of purchase will apply.