Free tools Windows power users keep installed

One-click scans. No signup required.

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.

iTechGuides is reader-supported. When you buy through links on our site, we may earn an affiliate commission. As an Amazon Associate I earn from qualifying purchases. Learn more

Put the cobot arm, controller and supporting cell equipment in a dedicated operational-technology (OT) zone, not on the office or guest wireless network. First inventory the robot’s real communications, then enforce only those documented flows at a firewall or gateway between zones. Keep guest Wi‑Fi on an isolated, internet-only network, and validate control, monitoring, maintenance and safety functions after every rule change.

A VLAN or subnet is useful for separating traffic, but it is not the complete control. The boundary must also decide which sources, destinations, protocols and ports may cross. Required communications differ by cobot model, software revision, PLC/HMI design and any remote-support or cloud service, so obtain the exact manufacturer and integrator requirements before writing ACLs.

What a properly segmented cobot network looks like

Use zones with controlled conduits between them rather than treating the whole workplace LAN as trusted. A practical design normally contains at least three logical areas:

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.
Zone Typical contents Permitted relationship to the cobot cell
OT/cobot cell Robot arm and controller, cell switch, PLCs, HMIs, safety-related systems and other equipment required for the process Only documented operational, engineering and support flows; deny everything else
Corporate/office Business laptops, servers, identity services and ordinary wired or employee Wi‑Fi clients No unsolicited connections into the robot; allow only specifically justified services, such as an approved engineering workstation workflow
Guest Wi‑Fi Visitors’ phones, tablets and unmanaged laptops Internet access only; no route to OT or corporate networks, with wireless client isolation enabled where available
DMZ or controlled-services zone Historian, broker, update repository, jump host or a cloud connector that genuinely needs data from OT Explicit, narrow conduits in the required direction; never a general bridge

The exact topology depends on criticality, legacy equipment, availability requirements and site policy. NIST’s SP 800-82 Rev. 3 describes using firewalls and gateways configured from mapped data flows for isolation; for high-criticality devices, physically separate switches may be appropriate instead of relying solely on logical separation.

#1 Best Overall
Moxa nat-102-2 Ports Industrial Network Address Translation Devices, -10 to 60°C. NAT
  • User-friendly NAT functionality simplifies network integration
  • Hands-free network access control through automatic whitelisting of locally connected devices
  • Integrated security features to ensure device and network safety
  • Ultra-compact size and robust industrial design suitable for cabinet installation
  • Supports secure boot for checking system integrity

The UK National Cyber Security Centre summarizes the purpose as follows: “Network segmentation involves dividing the OT network into distinct zones to enhance security and reduce the attack surface.” See Principle 4: Identify and document connectivity within your OT system.

Why a separate VLAN alone is insufficient

A VLAN or subnet separates broadcast domains and makes policy easier to apply, but it does not automatically prevent routing between them. A misconfigured trunk, permissive inter-VLAN routing rule, dual-homed device or wireless bridge can still expose the controller. The security boundary is the combination of:

  • Separate addressing and switching domains for OT, corporate and guest traffic.
  • A routed firewall, gateway or equivalent enforcement point between zones.
  • Default-deny rules that permit only documented source, destination, protocol and port combinations.
  • Administrative controls that prevent unauthorized changes to switches, access points and firewall policy.
  • Monitoring and review of the traffic that actually crosses the boundary.

For a low-criticality cell, logical segmentation may be adequate when it is correctly enforced and monitored. A process whose outage or compromise could cause serious safety, production or regulatory consequences may justify a physically separate switch fabric or stronger one-way architecture. The cited OT guidance does not prescribe one appliance or topology for every installation.

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.

Step 1: Inventory every cobot asset and owner

Do not start by blocking ports. Start with an asset and dependency list maintained by the controls engineer, network team and system owner. Include equipment that is easy to overlook:

  • The cobot arm and controller, including model and software revision.
  • PLCs, HMIs, teach pendants, safety PLCs, scanners and other safety-related systems.
  • Cell switches, engineering laptops, programming stations and maintenance consoles.
  • Historians, manufacturing execution systems, time sources, identity or certificate services and update repositories that the cell actually uses.
  • Remote-support jump hosts, VPN concentrators and cloud monitoring connectors, if present.
  • Any wireless device installed in or near the cell, including service laptops and handhelds.

Record an owner and business purpose for each asset. “The robot needs the network” is not sufficient: identify the exact peer and function, such as downloading a program from an engineering station, sending production data to a historian or receiving a time update.

Step 2: Build a communication matrix before creating rules

For each required flow, capture all of the following:

Rank #2
Vrupin 32 Piece Closed Rubber Grommet Firewall Solid Closed Hole Plug Kit, Tower and Round Double Sided Rubber Hole Plugs for Wire Electrical Plumbing Systems.
  • Great Variety of Sizes: 32 Pcs of the most commonly used 15 sizes assorted rubber grommet assortment kit.With retractable box cutter and velcro straps
  • High Quality: Rubber washers are made of flexible and durable rubber material, they are of good electric resistance capability.
  • Easy To Use: Wire grommets are quicker and easier to install since they can be placed on one side only.
  • Wide Range of Applications: Very useful for auto and other projects where wiring cable needs to be run through metal or plastic openings.
  • Packaging Includes:2-3/8''Drill Hole(2 Pcs),2''Drill Hole(2 Pcs)(2 Pcs),1-9/16''Drill Hole(2 Pcs),1-3/8''Drill Hole(2 Pcs),1-3/16''Drill Hole(2 Pcs),1''Drill Hole(2 Pcs),7/8''Drill Hole(2 Pcs),2-3/8''Drill Hole(2 Pcs),2''Drill Hole(2 Pcs),1-9/16''Drill Hole(2 Pcs),1-3/8''Drill Hole(2 Pcs),1-3/16''Drill Hole(2 Pcs),1''Drill Hole(2 Pcs),7/8''Drill Hole(2 Pcs),13/16''Drill Hole(2 Pcs).With retractable box cutter and velcro straps
Field What to record
Source and destination Specific device names, IP addresses or tightly scoped address objects; avoid “any” when a real endpoint is known
Direction Which side initiates the connection and whether replies are statefully allowed
Protocol and port TCP or UDP and the exact port range; document application protocols where known
Purpose Control, programming, monitoring, safety-related support, time, name resolution, updates or another stated function
Owner and evidence Responsible team plus the current manufacturer manual, integrator design or approved operational requirement
Availability requirement Whether loss of the flow stops production, affects safety, or merely delays reporting

The NCSC guidance calls for documenting asset communication needs, protocols and ports, existing controls, constraints and possible compromise paths. Keep the matrix under change control and review it whenever the robot program, software, PLC, HMI, remote-access method or monitoring service changes.

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.

Universal Robots’ published cybersecurity requirements illustrate the least-privilege approach: “There must be no inbound connections from adjacent networks to the robot,” and “Outgoing connections from the robot are to be restricted to allow the smallest relevant set of specific ports, protocols and addresses.” Those statements apply to the documented robot/software context; verify the current manual for your exact deployment at Universal Robots’ cybersecurity requirements.

Step 3: Draw zones and controlled conduits

Place the cobot controller and cell devices in the OT zone. Put office systems in the corporate zone and all visitor wireless clients in the guest zone. If OT data must leave the cell, use a DMZ or controlled-services zone rather than connecting the controller directly to the office LAN or public internet.

Logical separation

Separate VLANs and subnets are often practical when existing switches support them. Assign dedicated address pools, routing interfaces and access-control policies to each zone. Ensure switch trunks carry only the VLANs required at each link, disable unused ports and prevent an access point from bridging guest traffic into OT.

Physical separation

Use separate switches, cabling or security appliances when the cell’s criticality, legacy equipment, threat model or policy demands a boundary that is harder to bypass. Physical separation can also simplify fault isolation, but it does not remove the need for firewall policy, device hardening and monitoring.

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.

Controlled conduits

Every connection between zones should have a named source, destination, purpose, protocol and owner. A stateful firewall can permit replies to an approved session without allowing a new session in the opposite direction. Where a service must be reachable from corporate systems, expose only the required intermediary or jump host, not the controller’s entire subnet.

Step 4: Enforce least-privilege firewall and ACL rules

At the OT boundary, create explicit rules from the communication matrix. A generic policy pattern is:

  1. Allow an identified source address or address group to the identified OT destination, using only the documented protocol and port.
  2. Allow return traffic for that stateful session if the firewall supports state tracking.
  3. Deny and log other new inbound sessions from corporate, guest and adjacent networks.
  4. Restrict OT-initiated outbound traffic to the smallest relevant set of addresses, protocols and ports. Do not grant unrestricted web access merely because a controller has an update feature.
  5. Place the deny rule below all approved rules, and alert on repeated attempts so that undocumented dependencies are investigated rather than silently opened.

Do not assume that a port scan or a vendor’s generic list represents your installation. A controller may use different services after a software upgrade, and an integrator may have added a PLC, historian or remote-support dependency. Obtain written confirmation before changing a rule that could affect motion, programming, safety monitoring or recovery.

Example policy matrix

The following is a structure for documenting policy, not a list of ports to copy. Replace each entry with values verified for the deployed equipment.

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.
Source zone Destination Direction Policy intent
Approved engineering station Robot controller or programming service Corporate/DMZ to OT, only when initiated by the approved station Permit the manufacturer-supported programming or maintenance flow; deny other corporate clients
Robot controller Historian or monitoring collector OT to DMZ/services Permit only the documented telemetry protocol and destination
OT devices Approved time, name or update service OT outbound Allow only if the cell requires it, with fixed addresses and ports where possible
Guest clients Any OT address Guest to OT Deny and log; there should be no route
Office clients OT subnet Corporate to OT Deny by default; create a narrowly scoped exception only for a documented workflow

Step 5: Keep guest Wi‑Fi away from OT

Guest access should terminate in its own network with separate addressing, routing and access controls. The guest gateway should provide internet access without a route to either the OT or corporate address space. Enable wireless client isolation (also called peer-to-peer or intra-BSS isolation) so one visitor cannot directly reach another visitor’s device.

The UK Cabinet Office guidance on sharing workplace wireless networks recommends separation by network class, appropriate routing and access controls, and isolation between Wi‑Fi clients. If a wireless device must provide services to other networks, the guidance says to move it to a different VLAN rather than leaving it on the guest segment.

Do not solve coverage problems by placing an access point in the OT VLAN without reviewing its management, encryption and bridging behavior. If technicians need wireless access for commissioning, use an explicitly approved, authenticated maintenance network with a time-limited path to the required service—not the visitor SSID.

Rank #4
MOXA EDR-810-2GSFP Industrial Secure Router Switch--- NO VPN--- with 8 10/100BaseT(X) Ports, 2 1000BaseSFP Slots, 1 WAN, Firewall/NAT, -10 to 60C
  • MOXA EDR-810-2GSFP Industrial Secure Router Switch with 8 10/100BaseT(X) ports, 2 1000BaseSFP slots, 1 WAN, Firewall/NAT, -10to60C -- NO VPN --

Step 6: Harden the devices inside the OT zone

Segmentation limits exposure but does not make the controller or PLC secure by itself. Apply the manufacturer’s supported hardening settings, remove unused services and interfaces, change default credentials, restrict administrative accounts and keep firmware and software within the vendor’s supported lifecycle. Disable unused switch ports and management protocols where the equipment supports it.

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.

Use a dedicated management path or jump host for administration. Restrict who can alter firewall, switch and access-point configuration, and record approvals for each change. If a vendor requires remote support, define the initiating party, authentication method, allowed time window, destination and emergency disconnect procedure before enabling it.

Step 7: Monitor, test and document the boundary

Before applying a change, document the current configuration and a rollback path. Coordinate with the controls engineer or integrator so testing cannot create an unexpected motion or safety condition. Then validate in the real deployment:

  1. Confirm the controller can perform its normal cycle and that safety-related functions remain available.
  2. From an approved engineering station, test each documented programming or maintenance flow.
  3. Verify required telemetry, historian, time, name-resolution and update functions, if those services are part of the matrix.
  4. From a corporate workstation, attempt an unapproved connection and confirm it is denied and logged.
  5. From a guest client, verify internet access, client isolation and the absence of routes to OT and corporate addresses.
  6. Check that a firewall, switch or link failure produces the intended fail-safe behavior and that operators know how to isolate and restore connectivity.

Review logs for both permitted and denied traffic. A denial may reveal an undocumented dependency; an unexpected permit may reveal an overly broad address object or rule order. Do not “fix” a failed test by opening any-to-any access. Update the matrix, obtain owner approval and create the narrowest justified exception.

Independent reader supportYour contribution helps us test, update, and keep practical guides available for everyone.Support on Ko-Fi

Step 8: Plan recovery and operational continuity

OT availability can matter as much as confidentiality. Define how operators will continue safely if the firewall, switch, wireless controller or upstream service fails. Keep an offline or otherwise protected copy of approved configurations, contact details for the controls team and integrator, and a tested procedure for isolating the cell from other networks.

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.

Document the conditions for emergency access, who may authorize it and how it will be removed afterward. Schedule maintenance during a window that accounts for production and safety constraints. The joint guidance Secure connectivity principles for Operational Technology, published and reviewed on 15 January 2026, emphasizes operational constraints, boundary controls and defense in depth rather than a single security product.

Best Value
MOXA EDR-810-2GSFP-T - Industrial Secure Router with Switch/Firewall/NAT - NO VPN- 8 10/100BaseT(X) Ports, 2 1000BaseSFP Slots, 1 WAN, -10 to 75C
  • 8+2G all-in-one firewall/NAT --- NO VPN-------/router/switch
  • Build up secure remote access tunnel / Protect critical assets by stateful firewall
  • Inspect industrial protocol with PacketGuard technology / Easy network setup with network address translation (NAT)
  • RSTP/Turbo Ring redundant protocol enhances network redundancy / -40 to 75°C operating temperature range
  • Security features based on IEC 62443 / NERC CIP / Check firewall settings with intelligent SettingCheck feature

Choosing an implementation: questions that matter

If you are evaluating a firewall, gateway or segmentation architecture, compare capabilities against the actual traffic matrix rather than choosing by product category alone.

Decision area Questions to ask
Enforcement Can it filter the required source, destination, protocol and port combinations, and deny by default?
OT protocol handling Does it support the cobot’s actual protocols and any required inspection without disrupting timing or control?
Availability and safety What happens when the device, link or power fails? Can maintenance occur without creating an unsafe or uncontrolled state?
Monitoring Are rule hits, denies, configuration changes and health events logged in a form the team can review?
Lifecycle Can the device be patched, backed up and supported for the expected service life, including legacy OT equipment?
Topology Is logical segmentation sufficient for the cell’s criticality, or is a physical boundary warranted?
Integration Does the design support the exact robot model, software revision, PLC/HMI, engineering workflow and approved remote access?

An industrial firewall is a plausible product category, not a universal recommendation. Select it only after the communication inventory, availability requirements and failure behavior are understood.

Common mistakes and how to correct them

“The VLAN is isolated, so we are finished.”

Check inter-VLAN routing, trunk membership, firewall rule order and dual-homed devices. Add an enforcing boundary and test from each source zone.

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.

Allowing the whole office subnet for convenience

Replace broad address objects with named engineering stations or a controlled jump host. Limit the protocol and port, require authentication and log the session.

Putting guests on the corporate SSID

Create a separate guest network, remove routes to corporate and OT prefixes, and enable client isolation. Verify the result from an actual guest device.

Blocking first and discovering dependencies during production

Build the matrix with the manufacturer and integrator, use a controlled maintenance window, monitor denies and keep a tested rollback. Never infer required ports solely from a generic internet list.

Forgetting non-robot equipment

Include PLCs, HMIs, safety systems, historians, time services, update sources and remote-support paths. A controller can be segmented while a connected engineering laptop remains an uncontrolled bridge.

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.

Assuming segmentation replaces hardening

Continue credential management, patching, service reduction, backup, monitoring and incident response inside the OT zone. Segmentation reduces reachable attack paths; it does not remove vulnerabilities in trusted devices.

Maintenance checklist

  • Review the asset and flow inventory after every robot, PLC, HMI, software or network change.
  • Reconfirm manufacturer requirements against the exact model and deployed software revision.
  • Audit firewall, switch and access-point rules for unused objects, expired exceptions and overly broad sources.
  • Check that guest isolation and no-route controls still work after wireless or routing changes.
  • Review permitted and denied logs for unexpected peers, ports or repeated probes.
  • Test backup restoration and the documented isolation and recovery procedure.
  • Reassess whether the cell’s criticality now warrants physical separation or a different conduit design.

Bottom line for a cobot deployment

Separate the cobot cell from office and guest Wi‑Fi, but treat segmentation as an engineered control rather than a checkbox. Inventory real dependencies, place zones behind an enforcing boundary, allow only justified flows, isolate guest clients and validate the result with the people responsible for controls and safety. Because ports, protocols and failure consequences vary by deployment, the correct rule set is the one documented and tested for that specific cobot—not a copied template.

Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon at the time of purchase will apply.